2013
DOI: 10.3390/s130202484
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Micrococcus Luteus Biofilm Formation in Microfluidic Environments by pH Measurement Using an Ion-Sensitive Field-Effect Transistor

Abstract: Biofilm formation in microfluidic channels is difficult to detect because sampling volumes are too small for conventional turbidity measurements. To detect biofilm formation, we used an ion-sensitive field-effect transistor (ISFET) measurement system to measure pH changes in small volumes of bacterial suspension. Cells of Micrococcus luteus (M. luteus) were cultured in polystyrene (PS) microtubes and polymethylmethacrylate (PMMA)-based microfluidic channels laminated with polyvinylidene chloride. In microtubes… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 29 publications
(12 citation statements)
references
References 26 publications
0
11
0
1
Order By: Relevance
“…Literature concerning biofilm‐formation of the other pathogens only detected by sonification is scarce. These rather rare pathogens definitely need to be further investigated in regards of biofilm formation …”
Section: Discussionmentioning
confidence: 99%
“…Literature concerning biofilm‐formation of the other pathogens only detected by sonification is scarce. These rather rare pathogens definitely need to be further investigated in regards of biofilm formation …”
Section: Discussionmentioning
confidence: 99%
“…Em relação aos alimentos, a água mineral envasada vem sendo motivo de preocupação pela fácil contaminação por Pseudomonas aeruginosa, cando sob responsabilidade da empresa envasadora a análise das características microbiológicas na fonte, poço e no produto nal (ANVI-SA Resolução nº 310/1999). Outra bactéria formadora de bio lme, encontrada, também, na amostra 1I, é a espécie Micrococcus luteus (Matsuura et al, 2013).…”
Section: Isolamento E Identi Cação Das Linhagens Bacterianasunclassified
“…We evaluated the effect of the turbulent method from the sensor signal directly. The sensor probe responded quickly (msec order) because the pH-sensitive region of the pH-FET used in the instrument was coated with Ta 2 O 5 [ 39 , 40 , 41 , 42 , 43 ]. This rapid response made it possible to monitor the transient characteristics of the measurement directly from the sensor signal.…”
Section: Resultsmentioning
confidence: 99%