2007
DOI: 10.1021/ac061269p
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Multiple Proteins on One Spot by Laser Ablation Inductively Coupled Plasma Mass Spectrometry and Application to Immuno- Microarray with Element-Tagged Antibodies

Abstract: Inductively coupled plasma mass spectrometry (ICPMS) has been successfully used for the detection of element-tagged biomolecules with the advantage of multielement capability. However, this technique cannot be used for microarray detection due to the necessity to dissolve the elemental tags before introducing them to the plasma source. Here, we report the detection of multiple proteins on each spot of the immuno-microarray by laser ablation ICPMS. alpha-Fetoprotein IgG (AFP), carcinoembryonic antigen (CEA), an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
114
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
8
2

Relationship

4
6

Authors

Journals

citations
Cited by 186 publications
(114 citation statements)
references
References 30 publications
0
114
0
Order By: Relevance
“…It provides an alternative strategy to count the number of OSHs and OSOSO involved, offering valuable information for proteomic studies. Such information is not only important to protein chemistry, but also crucial to the quantitative analysis of peptides and/or proteins when a hard ionization source mass spectrometry, such as inductively coupled plasma mass spectrometry (ICP-MS) [18,19], is applied to overcome the relatively low ionization ability of ESI-MS for labeled peptides and/or proteins. Both quantification of a protein and locating OSHs and OSOSO in a protein with ESI-MS together with ICP-MS using RHg ϩ as a tag will be the subjects of future studies.…”
Section: Resultsmentioning
confidence: 99%
“…It provides an alternative strategy to count the number of OSHs and OSOSO involved, offering valuable information for proteomic studies. Such information is not only important to protein chemistry, but also crucial to the quantitative analysis of peptides and/or proteins when a hard ionization source mass spectrometry, such as inductively coupled plasma mass spectrometry (ICP-MS) [18,19], is applied to overcome the relatively low ionization ability of ESI-MS for labeled peptides and/or proteins. Both quantification of a protein and locating OSHs and OSOSO in a protein with ESI-MS together with ICP-MS using RHg ϩ as a tag will be the subjects of future studies.…”
Section: Resultsmentioning
confidence: 99%
“…The nanoparticles tagged on biological molecules could be detected by ICP-MS, which has been demonstrated by Baranov et al [20], Merkoci et al [21], and our group [22,23] in recent years. An important advantage of ICP-MS for nanoparticle detection is that high sensitivity could be obtained because of large quantities of detectable atoms in each nanoparticle tag.…”
mentioning
confidence: 99%
“…Label-free immunoassays are difficult to develop because of the lack of a detectable protein signal or a signal too weak to quantify the trace amount of analytes (14 ). Labeled probe methods such as multilabel and spatially resolved assays can offer amplified detection signals for multianalyte immunoassays.…”
mentioning