1981
DOI: 10.1002/jhrc.1240040503
|View full text |Cite
|
Sign up to set email alerts
|

Detection of PAH of molecular weight between 300 and 402 in airborne particulate matter by fused silica capillary GC and GC/MS

Abstract: SummaryGas chromatography (GC), low-voltage mass spectrometry (LV MS), and gas chromatography/mass spectrometry (GUMS) have been used for detecting polycyclic aromatic hydrocarbons (PAH) of molecular weight between 300 and 402 in airborne particulate matter. Nearly 200 high molecular PAH separated by fused silica capillary columns could be characterized by their El mass spectra. The lack of reference substances precluded further structure elucidation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
9
1

Year Published

1983
1983
1992
1992

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 9 publications
0
9
1
Order By: Relevance
“…Additionally dibenzo[bc,fc/]coronene [374(1)] and dicyclopenta[oj]coronene [374(2)] were rejected as possible components in the extract based on the predicted ( + H)+/M+ values. Dibenzo[e,g/w]indeno[l,2,3,4-p<jra]perylene [374 (5)] has been reported to be in the carbon black (6), but our calculated ( + H)+/M+ ratio does not support this. The experimental ( + H)+/M+ ratios of 0.521 and 0.917 fall outside the 90% confidence interval (Figure 5) for dibenzo-[e,g/»]indeno[l,2,3,4-pqra]perylene [374(5)].…”
Section: Resultscontrasting
confidence: 66%
See 4 more Smart Citations
“…Additionally dibenzo[bc,fc/]coronene [374(1)] and dicyclopenta[oj]coronene [374(2)] were rejected as possible components in the extract based on the predicted ( + H)+/M+ values. Dibenzo[e,g/w]indeno[l,2,3,4-p<jra]perylene [374 (5)] has been reported to be in the carbon black (6), but our calculated ( + H)+/M+ ratio does not support this. The experimental ( + H)+/M+ ratios of 0.521 and 0.917 fall outside the 90% confidence interval (Figure 5) for dibenzo-[e,g/»]indeno[l,2,3,4-pqra]perylene [374(5)].…”
Section: Resultscontrasting
confidence: 66%
“…As discussed previously, we proposed peak E to be either benzo[cd]naphtho[3,2,l,8-pqra]perylene [350(4)] or benzo-[ (m ] naphtho [ 2,1,8-gra ] perylene [350 (5)]. We now have assigned benzo[cd]naphtho[3,2,l,8-pgro]perylene [350(4)] to peak G. Therefore, we predict that peak E is benzo[lmn]naphtho[2,l,8-qra]perylene [350(5)].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations