2005
DOI: 10.1016/j.jchromb.2005.06.007
|View full text |Cite
|
Sign up to set email alerts
|

Detection of prenatal exposure to several classes of environmental toxicants and their metabolites by gas chromatography–mass spectrometry in maternal and umbilical cord blood

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
33
0
8

Year Published

2006
2006
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 47 publications
(42 citation statements)
references
References 42 publications
(44 reference statements)
1
33
0
8
Order By: Relevance
“…In blood, the matrix-spiked calibration curves were linear for all parent pesticides and pesticide metabolites with coefficients of linearity greater than 0.990 (25). Optimum recovery rates ranged from 84-142% for parent compounds and 54-122% for the metabolites.…”
Section: Bloodmentioning
confidence: 94%
See 1 more Smart Citation
“…In blood, the matrix-spiked calibration curves were linear for all parent pesticides and pesticide metabolites with coefficients of linearity greater than 0.990 (25). Optimum recovery rates ranged from 84-142% for parent compounds and 54-122% for the metabolites.…”
Section: Bloodmentioning
confidence: 94%
“…Lindane and DDT were also analyzed based on our previous study in Manila, Philippines that showed substantial exposure to these pesticides (22). Some known metabolites of these pesticides were also analyzed including: 2-isopropoxyphenol [ The pesticides and their metabolites were analyzed in the various matrices by gas chromatography/mass spectrometry (GC/MS) using published procedures (21)(22)(23)(24)(25) and with the following analytical characteristics:…”
Section: Methodsmentioning
confidence: 99%
“…Ainsi Corion et coll. [58] ont décrit une méthode GC-EI-MS pour doser des pesticides de classes variées et leurs métabolites dans le sang maternel et le cordon ombilical. Cette méthode utilise la LLE et fournit des LOD de moins de 0,10 à 2 μg/mL pour le pesticide parent et ses métabolites respectivement.…”
Section: Méthodes « Multirésiduelles »unclassified
“…Identification was further ascertained using target to qualifier ion response ratios. The mean response ratios were calculated from target to qualifier ion response ratios obtained from the analysis of spiked calibrators and the limits were set at ± 20% of the mean response ratios [21,26,27]. The limit of detection (LOD) was established using the empirical approach [28].…”
Section: Quantitation and Identificationmentioning
confidence: 99%