2012
DOI: 10.3892/ol.2012.890
|View full text |Cite
|
Sign up to set email alerts
|

Detection of single tumor cell resistance with aptamer biochip

Abstract: Abstract. In this study, a novel RNA aptamer biochip was developed for tumor cell capture and detection of single cell resistance. This biochip consists of a polydimethylsiloxane (PDMS) cover containing a channel for introducing cells and sustaining their activity and microelectrode matrix on a silicon dioxide layer. Epidermal growth factor receptor (EGFR) aptamers which specifically identify and isolate tumor cells were attached in the gap between two electrodes. After cell biochip incubation, surplus tumor c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
2

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 24 publications
(11 citation statements)
references
References 29 publications
0
9
0
2
Order By: Relevance
“…Con el algoritmo "Droplet routing" aplicado al dispositivo, se prueba entonces todo el biochip usando menor tiempo [19]. Con relación a nucleicos, se ha desarrollado, por último, un biochip conformado por un aptámero de ARN para la captura de células tumorales y la detección de resistencia a células individuales [20].…”
Section: Algoritmounclassified
“…Con el algoritmo "Droplet routing" aplicado al dispositivo, se prueba entonces todo el biochip usando menor tiempo [19]. Con relación a nucleicos, se ha desarrollado, por último, un biochip conformado por un aptámero de ARN para la captura de células tumorales y la detección de resistencia a células individuales [20].…”
Section: Algoritmounclassified
“…Anti-EGFR aptamers have also been used in a unique way by Wang et al This group generated a biochip with RNA aptamers coating a microelectrode on a silicon dioxide layer [67]. The biochip contains a PDMS cover with a channel for introducing cells.…”
Section: Aptamer-based Technologies For Ctc Enrichment/capturementioning
confidence: 99%
“…1-2 μg/mL), and other fluorescent aptasensors [53]. Notably, being compared to voltage current and electrochemical methods, homogeneous detection is robust, rapid and does not affect interacting surfaces of the biomolecules which can be detected without the need for additional steps and reagents [54,55].…”
Section: Fluorescent Oligonucleotides In Direct Sensing Of Autoantibomentioning
confidence: 99%