2003
DOI: 10.1097/01.prs.0000054768.14922.44
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Subclinical Infection in Significant Breast Implant Capsules

Abstract: The pathogenesis of fibrous capsular contracture after augmentation mammaplasty is still debated. One hypothesis implicates low-grade bacterial infections as a cause. The presence of a staphylococcal biofilm in a patient with recurrent capsular contracture was previously reported. A comparative, prospective, blinded, clinical study of implants and capsules removed from patients with or without significant capsular contracture was conducted to investigate the association of biofilm contamination, breast implant… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
180
1
14

Year Published

2009
2009
2016
2016

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 340 publications
(199 citation statements)
references
References 27 publications
4
180
1
14
Order By: Relevance
“…Then each of the plate was placed in a sterile tube with 20 mL phosphate-buffered saline and sonicated (Branson Ultrasonic Cleaner; Branson Ultrasonics, Danbury, CT, USA) at a frequency of 50 kHz for 5 min. Previous studies [29][30][31][32][33] have proven the efficiency of such ultrasonic treatment for removing any bacteria that attach to the plates without leading to the death of bacteria. After sonication, an aliquot of the solution was collected and submitted for further microbiologic culture (n = 200 for plates) and PCR processing.…”
Section: Follow-up Examinationmentioning
confidence: 99%
“…Then each of the plate was placed in a sterile tube with 20 mL phosphate-buffered saline and sonicated (Branson Ultrasonic Cleaner; Branson Ultrasonics, Danbury, CT, USA) at a frequency of 50 kHz for 5 min. Previous studies [29][30][31][32][33] have proven the efficiency of such ultrasonic treatment for removing any bacteria that attach to the plates without leading to the death of bacteria. After sonication, an aliquot of the solution was collected and submitted for further microbiologic culture (n = 200 for plates) and PCR processing.…”
Section: Follow-up Examinationmentioning
confidence: 99%
“…Una vez pasada la pubertad se considerará plantear el cambio de esta por una que vaya en relación con el tamaño testicular del momento (17). Si el paciente se encuentra satisfecho con el tamaño de su primera prótesis, debe evitarse una nueva intervención quirúrgica (18,21).…”
Section: Discussionunclassified
“…Se detectaron cultivos positivos más frecuentemente en el primer grupo (p = 0,0006) y la mayoría de los microorganismos aislados fueron Staphylococcus coagulasa negativa, principalmente S. epidermidis. La microscopia electrónica confi rmó la presencia de biopelícula en el implante y dentro de la cápsula 8 .…”
Section: Discussionunclassified