2014
DOI: 10.3109/10428194.2013.871634
|View full text |Cite
|
Sign up to set email alerts
|

Detection of T-cell receptor γ gene rearrangement in paraffin-embedded T or natural killer/T-cell lymphoma samples using the BIOMED-2 protocol

Abstract: While the use of polymerase chain reaction (PCR)-based clonality analysis of formalin-fixed paraffin-embedded (FFPE) tissue has recently become widespread, the detection sensitivity for lymphoma subtypes using FFPE samples is not well known. Here, we analyzed T-cell receptor γ chain (TCRG) gene rearrangement clonality in 100 cases of T- or natural killer (NK)/T-cell lymphoma and examined detection sensitivity according to lymphoma subtype. Clonality was detected in approximately 80% of the major T-cell lymphom… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
13
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 9 publications
1
13
0
Order By: Relevance
“…The results were positive in 71% of the AITL. [15] The overall prognosis of these tumors is poor with a median survival less than three years in most studies (16). The treatment is mainly based on a conventional chemotherapy.…”
Section: Discussionmentioning
confidence: 99%
“…The results were positive in 71% of the AITL. [15] The overall prognosis of these tumors is poor with a median survival less than three years in most studies (16). The treatment is mainly based on a conventional chemotherapy.…”
Section: Discussionmentioning
confidence: 99%
“…T-cell receptor g chain (TCRG) VgIf and Vg10 primers (tube A) and TCRG Vg9 and Vg11 primers (tube B) were used for TCR gene rearrangement study, and each of the tubes (A and B) also included 2 primers targeting the J segments (Jg1.1/2.1 and Jg1.3/Jg2.3) as previously reported. 12 11 The products of PCR reactions were subsequently analyzed by ABI PRISM 310 Genetic Analyzer and Gene Mapper software version 3.7 (Applied Biosystems, CA).…”
Section: Polymerase Chain Reaction For Immunoglobulin Heavy Chain Andmentioning
confidence: 99%
“…A convention used in the laboratory at Colorado State University is to call a result positive (clonal) if the clonal peak is three times the height of the baseline, in accordance with recently published human studies (Miyata-Takata et al, 2014). A convention used in the laboratory at Colorado State University is to call a result positive (clonal) if the clonal peak is three times the height of the baseline, in accordance with recently published human studies (Miyata-Takata et al, 2014).…”
Section: Discussionmentioning
confidence: 92%