Detection ofsalmonella typhimurium by hand-held ion mobility spectrometer: A quantitative assessment of response characteristics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
11
0

Year Published

2001
2001
2017
2017

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(12 citation statements)
references
References 14 publications
1
11
0
Order By: Relevance
“…IMS is well-known for applications like the detection of chemical warfare agents, explosives, and drugs (Eiceman and Karpas 2005; Baumbach and Eiceman 1999; Roehl 1991). New applications in recent years are microbial VOC detections in headspace of microbial cultures (Ruzsanyi et al 2002; Snyder et al 1991; Smith et al 1997; Perl et al 2011) or even over clinical samples directly (Chaim et al 2003). Also differential mobility spectrometry, a closely related technology, has been used for that purpose already (Shnayderman et al 2005).…”
Section: Introductionmentioning
confidence: 99%
“…IMS is well-known for applications like the detection of chemical warfare agents, explosives, and drugs (Eiceman and Karpas 2005; Baumbach and Eiceman 1999; Roehl 1991). New applications in recent years are microbial VOC detections in headspace of microbial cultures (Ruzsanyi et al 2002; Snyder et al 1991; Smith et al 1997; Perl et al 2011) or even over clinical samples directly (Chaim et al 2003). Also differential mobility spectrometry, a closely related technology, has been used for that purpose already (Shnayderman et al 2005).…”
Section: Introductionmentioning
confidence: 99%
“…First experiences have been made in the detection of microbial VOCs by IMS (Snyder et al 1991; Smith et al 1997; Chaim et al 2003) and the related technology of differential mobility spectrometry (Shnayderman et al 2005). Coupling IMS with a multicapillary column for pre-separation facilitates the analysis of complex and humid gas samples (Ruzsanyi et al 2005), such as human breath.…”
Section: Introductionmentioning
confidence: 99%
“…Reliable quantitative response from GC-DMS analyses is necessary for chemometric processing of measurements and APCI sources are known to exhibit limited linear ranges and source saturation [31]. Results from measurements of standards are shown in Figure 4 and The precision of quantitative response is shown in Table 2 with peak areas, standard deviation of peak area, and percent relative standard deviation (% RSD) of peak area are listed for each correctly predicting the test set's feedstocks fostered some confidence in the PCA and HCA models.…”
Section: Quantitative Performancementioning
confidence: 99%