2019
DOI: 10.1016/j.microc.2019.03.087
|View full text |Cite
|
Sign up to set email alerts
|

Detection oxidative degradation in lubricating oil under storage conditions using digital images and chemometrics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 16 publications
(16 citation statements)
references
References 21 publications
0
13
0
Order By: Relevance
“…Glass, quartz or prismatic PTFE cuvettes 17,[29][30][31] and flow cells 32,33 have been used similarly to spectrophotometry involving specific colorimetric reactions, replacing exclusively the detector. Other common holders have included glass, plastic and lab-made polytetrafluorethylene (PTFE) Petri plates 25,27,28,[34][35][36][37][38][39][40][41][42][43][44][45][46] have been the most employed holder type to dispose the samples directly without pretreatment. PTFE chambers of automated Flow-Batch Analyzers 26,47 have been also used to prepare samples and calibration solutions in flow into the mixing chamber.…”
Section: Instrumentation For Cachasmentioning
confidence: 99%
See 3 more Smart Citations
“…Glass, quartz or prismatic PTFE cuvettes 17,[29][30][31] and flow cells 32,33 have been used similarly to spectrophotometry involving specific colorimetric reactions, replacing exclusively the detector. Other common holders have included glass, plastic and lab-made polytetrafluorethylene (PTFE) Petri plates 25,27,28,[34][35][36][37][38][39][40][41][42][43][44][45][46] have been the most employed holder type to dispose the samples directly without pretreatment. PTFE chambers of automated Flow-Batch Analyzers 26,47 have been also used to prepare samples and calibration solutions in flow into the mixing chamber.…”
Section: Instrumentation For Cachasmentioning
confidence: 99%
“…Ribeiro et al 27 identified degradations in commercial lubricating oils, simulating storage conditions by heating in an oven at 60 C and radiation by UV exposition at different times (3,6, and 9 h). Accuracy, sensibility, and specificity rates of 100% were obtained for distinguishing nonoxidized samples from samples that have suffered an oxidation process using Grayscale+RGB + HSI histogram and PLS-DA.…”
Section: Forensic Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…By evaluating the works that used smartphones for image acquisition and performed the external processing of the acquired data (Figure 1), we can see that these devices are explored in several areas, such as the detection of diseases and markers of diseases causing in the medical field, immunoassay, 18–27 quality control of the environment, 28–39 forensic analysis, 40–42 control and quality of beverages and food, 15,43–64 quality evaluation of pharmaceutical products, 54,65,66 fuel quality control, 67,68 pigments, 69 chemical education, kinetic studies, and chemical receptors 70–77 …”
Section: Introductionmentioning
confidence: 99%