2010
DOI: 10.1016/j.amjsurg.2010.02.001
|View full text |Cite
|
Sign up to set email alerts
|

Determinants of Tc-99m sestamibi SPECT scan sensitivity in primary hyperparathyroidism

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
12
0
1

Year Published

2011
2011
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(14 citation statements)
references
References 22 publications
1
12
0
1
Order By: Relevance
“…With these parameters, the spillover is lower than 1% in 123 I window and 10% in 99m Tc window. 13 Hindié et al 7 have used wider symmetrical window for 99m Tc (T7.5%) and asymmetrical window (range, 4% to +10%) for 123 I, which could also account for high sensitivity reported.…”
Section: Impact Of Collimationmentioning
confidence: 95%
See 1 more Smart Citation
“…With these parameters, the spillover is lower than 1% in 123 I window and 10% in 99m Tc window. 13 Hindié et al 7 have used wider symmetrical window for 99m Tc (T7.5%) and asymmetrical window (range, 4% to +10%) for 123 I, which could also account for high sensitivity reported.…”
Section: Impact Of Collimationmentioning
confidence: 95%
“…Lesser sensitivity of scintigraphy for small enlarged gland is well known with 99m Tc-MIBI 13 and with dual-isotope 14 in planar and tomographic images. 8 In our study, scintigraphy was negative with the 2 protocols for 3 patients; the adenomas had small volume, inferior to 3.7 cm 3 (mean for all enlarged parathyroid is 9 cm 3 ).…”
Section: Impact Of Parathyroid Gland Volumementioning
confidence: 97%
“…17 The scan results are dependent on the size of the lesion and calcium levels. 18 US is a cheap, convenient and non-invasive modality that has a sensitivity of 73% and a positive predictive value of 100% in single parathyroid adenomas. 19 In competent hands, US is capable of providing precise anatomical detail that corresponds closely to surgical findings 92% of the time.…”
mentioning
confidence: 99%
“…However, there was poor agreement between the 2 studies in the localization of parathyroid adenoma (Table 4). Varied sensitivity of Tc 99m MIBI for parathyroid adenoma has been reported in previous studies, including 56% in 1 study [15] 45% in another [16] and 39% to 90% in a large meta-analysis of 52 studies [16]. Another study reported 90% sensitivity and 91% accuracy [17].…”
Section: Discussionmentioning
confidence: 86%