2021
DOI: 10.1016/j.talanta.2020.121637
|View full text |Cite
|
Sign up to set email alerts
|

Determination of 135Cs concentration and 135Cs/137Cs ratio in waste samples from nuclear decommissioning by chemical separation and ICP-MS/MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 35 publications
1
7
0
1
Order By: Relevance
“…290 In this work the instrument was tted with three electron multipliers and three Daly detectors, which allowed four isotopic signals to be monitored in any combination, and high-time resolution ampliers which allowed dwell times as short as 10 ms to be used to monitor the four Pt isotopes, m/z 194, 196, 197 and 198. Data presented for the 195 Pt : 194 Pt isotope ratio, which is naturally close to unity thus minimising the effects of mass bias, was always in agreement with, but lower than, the natural ratio. The uncertainties (2 SD) on the isotope ratios were 35% for 30 nm NPs, 17% for 50 nm NPs and 10% for 70 nm NPs with the precision obtained presumably improving due to the increasing ion signal with increasing NPs size for a given particle number concentration.…”
Section: Nanostructuressupporting
confidence: 56%
See 3 more Smart Citations
“…290 In this work the instrument was tted with three electron multipliers and three Daly detectors, which allowed four isotopic signals to be monitored in any combination, and high-time resolution ampliers which allowed dwell times as short as 10 ms to be used to monitor the four Pt isotopes, m/z 194, 196, 197 and 198. Data presented for the 195 Pt : 194 Pt isotope ratio, which is naturally close to unity thus minimising the effects of mass bias, was always in agreement with, but lower than, the natural ratio. The uncertainties (2 SD) on the isotope ratios were 35% for 30 nm NPs, 17% for 50 nm NPs and 10% for 70 nm NPs with the precision obtained presumably improving due to the increasing ion signal with increasing NPs size for a given particle number concentration.…”
Section: Nanostructuressupporting
confidence: 56%
“…In single quadrupole mode, numerous possibilities were identied over the mass range 227-239. The full list was tabulated, however the most important were: 194 Scanning at a higher mass range (227-270 a.m.u.) showed that higher oxides of matrix elements did not form or, if they did, they did not interfere with the analytes.…”
Section: Copper and Copper-based Alloysmentioning
confidence: 99%
See 2 more Smart Citations
“…While, this ratio decreases with increased neutron flux after a long-time neutron irradiation in a nuclear reactor because of the extremely large neutron capture cross section of 135 Xe, which is a decay precursor of 135 Cs in the fission production from nuclear fuel, causing a reduced yield of 135 Cs. The 135 Cs/ 137 Cs atomic ratio as low as 0.12 was observed in the high neutron flux reactor derived samples [19].…”
Section: Introductionmentioning
confidence: 90%