2008
DOI: 10.1016/j.jchromb.2007.11.037
|View full text |Cite
|
Sign up to set email alerts
|

Determination of 3-hydroxyisovalerylcarnitine and other acylcarnitine levels using liquid chromatography–tandem mass spectrometry in serum and urine of a patient with multiple carboxylase deficiency

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 34 publications
(23 citation statements)
references
References 19 publications
0
23
0
Order By: Relevance
“…LTryptophan-d 5 (L-Trp-d 5 ), used as an internal standard, was purchased from Cambridge Isotope Laboratories, Inc.. Trp and Kyn were measured using an ultra-high-performance liquid chromatography (UPLC) -tandem mass spectrometry (MS-MS, Quattro Premier XE mass spectrometer) system (Waters Corporation) as described previously (29). A 10-mL sample solution that was pretreated by a solid phase extraction (SPE) method using an Oasis MCX 30 mg/1 cc SPE cartridge (Waters Corporation) was injected into an Acquity UPLC BEH C18 column (2 Â 100 mm; Waters Corporation) at room temperature.…”
Section: Measurement Of Serum Trp and Kynmentioning
confidence: 99%
“…LTryptophan-d 5 (L-Trp-d 5 ), used as an internal standard, was purchased from Cambridge Isotope Laboratories, Inc.. Trp and Kyn were measured using an ultra-high-performance liquid chromatography (UPLC) -tandem mass spectrometry (MS-MS, Quattro Premier XE mass spectrometer) system (Waters Corporation) as described previously (29). A 10-mL sample solution that was pretreated by a solid phase extraction (SPE) method using an Oasis MCX 30 mg/1 cc SPE cartridge (Waters Corporation) was injected into an Acquity UPLC BEH C18 column (2 Â 100 mm; Waters Corporation) at room temperature.…”
Section: Measurement Of Serum Trp and Kynmentioning
confidence: 99%
“…In addition, these methods are not commonly performed together, so samples are analyzed by separate procedures using different instruments. The reported methods for acylcarnitines are not practical for second-tier testing due to long analysis times [9,18,19], poor chromatography [20], or involve alternative instrumentation such as capillary electrophoresis [11]. There are many methods available for amino acid analysis; however, the majority involves derivatization of samples followed by HPLC-UV, FLD, LC/MS or GC/MS [21].…”
Section: Introductionmentioning
confidence: 99%
“…The second-tier test described allows rapid separation and quantification of various C5 acylcarnitines which may underlie elevated C5 levels in routine newborn screening in the original blood sample (Janzen et al 2013). Maeda et al (2008Maeda et al ( , 2007 previously described the chromatographic separation of acylcarnitines from serum and urine. However, their method needs a second sample from the patients (urine or serum) and the sample preparation requires the use of solid phase extraction material (SPE).…”
Section: Discussionmentioning
confidence: 99%