1999
DOI: 10.1016/s0378-4347(99)00329-1
|View full text |Cite
|
Sign up to set email alerts
|

Determination of a novel calmodulin antagonist, 3-{2-[4-(3-chloro-2-methylphenyl)-1-piperazinyl]ethyl}-5,6-dimethoxy-1-(4-imidazolylmethyl)-1H-indazole dihydrochloride 3.5 hydrate, DY-9760e, in human plasma using solid-phase extraction and high-performance liquid chromatography with fluorescence detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2000
2000
2016
2016

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 6 publications
0
6
0
Order By: Relevance
“…To quantitatively analyze the DY distribution inside brain, the high-performance liquid chromatography–fluorescence detection (HPLC–FLD) method reported previously was used to determine the DY concentration . The results were illustrated in Figure B,C.…”
Section: Resultsmentioning
confidence: 99%
“…To quantitatively analyze the DY distribution inside brain, the high-performance liquid chromatography–fluorescence detection (HPLC–FLD) method reported previously was used to determine the DY concentration . The results were illustrated in Figure B,C.…”
Section: Resultsmentioning
confidence: 99%
“…Estimated plasma levels were calculated from pharmacokinetic data. Plasma concentrations of DY-9760e were measured according to the procedure of Tachibana et al [48] at 6 h of infusion at 0.5 mg/kg/h ($) and 24 h of infusion at 0.1 mg/kg/h (P), respectively. Estimated levels were consistent with the actual values.…”
Section: Discussionmentioning
confidence: 99%
“…Following dosing, the animals were housed in metabolic cages to collect urine and feces. In rats, 14…”
Section: Excretion Of Radioactivity In Rats and Monkeysmentioning
confidence: 99%
“…While under ether anesthesia, three male rats were instrumented with polyethylene cannulae (SP-10; Natsume, Tokyo, Japan), which were inserted into their bile ducts to allow for bile collection, and were placed in a Bollman cage. After the animals had recovered from anesthesia, 14 C-DY-9760e (4.03 MBq/kg) was intravenously injected as a bolus and the bile, urine, and feces were collected. In a separate enterohepatic circulation study, the bile (10 ml) obtained from these rats was injected at a dose of 110 µg of DY-9760/kg (443 kBq) into the duodenum of the recipient rats with cannulae.…”
Section: Bile Excretionmentioning
confidence: 99%
See 1 more Smart Citation