2011
DOI: 10.1016/j.chroma.2011.06.022
|View full text |Cite
|
Sign up to set email alerts
|

Determination of aliphatic amines by gas chromatography–mass spectrometry after in-syringe derivatization with pentafluorobenzoyl chloride

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(9 citation statements)
references
References 42 publications
0
9
0
Order By: Relevance
“…Compared with those of the reported direct CE-AD methods, [16][17][18][19] the LOD of EDA was remarkably reduced (13 pg/mL vs. 0.1 μmol/L-10 ng/mL) by the proposed method, which was nearly equivalent to those of HPLC-LIF [8] (0.5 nmol/L) and GC-MS [10] (1 pg/mL); and relatively good repeatability has been obtained based on short separation capillary. Besides, theophylline in Aminophylline Tablets does not interfere with the determination of EDA.…”
Section: Discussionmentioning
confidence: 42%
See 1 more Smart Citation
“…Compared with those of the reported direct CE-AD methods, [16][17][18][19] the LOD of EDA was remarkably reduced (13 pg/mL vs. 0.1 μmol/L-10 ng/mL) by the proposed method, which was nearly equivalent to those of HPLC-LIF [8] (0.5 nmol/L) and GC-MS [10] (1 pg/mL); and relatively good repeatability has been obtained based on short separation capillary. Besides, theophylline in Aminophylline Tablets does not interfere with the determination of EDA.…”
Section: Discussionmentioning
confidence: 42%
“…[6][7][8][9][10] High performance liquid chromatography (HPLC) [11] and gas chromatography (GC) [12,13] have been employed for the purpose. However, the above methods still have some drawbacks of low sensitivity, complicated derivatization procedures or high analytical cost.…”
Section: Introductionmentioning
confidence: 99%
“…The obtained results also demonstrated that even in cases where the derivatization reaction is performed on the fiber, Although this analysis time is comparable or slightly higher with respect to other derivatization SPME protocols [2,14,[25][26][27], it has the advantage of avoiding the addition of the derivatization agent to each sample which, can potentially constitute an additional source of error in the analysis routine. On the other hand, other extraction techniques such as vortex assisted liquidliquid microextraction [28], micro extraction in packed syringe (MEPS) [29], single drop microextraction (SDME) [30], air-assisted liquid-liquid microextraction (AALLME) [9], in syringe derivatization [6] used for determination of derivatized amines often lack automation options, employ organic solvents and include tedious procedures.…”
Section: Optimization Of Reaction Conditions In Aqueous Phasementioning
confidence: 99%
“…Amines undergo several derivatization reactions, which have been widely reviewed in the literature [3][4][5]. Acylation of the amino group with pentafluorobenzoyl chloride as a derivatization reagent was tested for the first time by Sanghi et al [6]. Silylation reaction was reported by Casal et al for the analysis of heterocyclic aromatic amines (HAAs) as their tert-butyldimethylsilyl (TBDMS) derivatives [7].…”
Section: Introductionmentioning
confidence: 98%
“…Sample preparation remains one of the more time-consuming and error-prone aspects of analytical chemistry. To overcome drawbacks of conventional extraction techniques, alternative miniaturized methods have been proposed both as solid phase microextraction, as Solid Phase MicroExtraction (SPME) [7][8][9], MicroExctraction by Packed Sorbent (MEPS) [10], Stir Bar Sorptive Extraction (Twister, SBSE) [11], Solid Phase Dynamic Extraction (Magic Needle, SPDE) [12], In-Tube Extraction (ITEX) [13] and liquid phase microextraction like Single-Drop MicroExtraction (SDME) [14], Hollow Fiber LiquidPhase Microextraction (HF-LPME) [15,16], Dispersive Liquid-Liquid Microextraction (DLLME) [17], Solvent Bar MicroExtraction (SBME) [18]. On-sample derivatizations applied in miniaturized extraction systems and their simultaneous GC and liquid chromatography analysis has been described for the determination of analytes in aqueous matrices [19,20].…”
Section: Introductionmentioning
confidence: 99%