Determination of Aroclor 1260 in soil samples by gas chromatography with mass spectrometry and solid-phase microextraction

Abstract: A novel fast screening method was developed for the determination of polychlorinated biphenyls that are constituents of the commercial mixture, Aroclor 1260, in soil matrices by gas chromatography with mass spectrometry combined with solid-phase microextraction. Nonequilibrium headspace solid-phase microextraction with a 100 μm polydimethylsiloxane fiber was used to extract polychlorinated biphenyls from 0.5 g of soil matrix. The use of 2 mL of saturated potassium dichromate in 6 M sulfuric acid solution impro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 27 publications
0
6
0
Order By: Relevance
“…In this study, as elsewhere, 100 µm PDMS fibers were found to be the most suitable for PCB analyses. 29,30,34…”
Section: Experimental Methodsmentioning
confidence: 99%
“…In this study, as elsewhere, 100 µm PDMS fibers were found to be the most suitable for PCB analyses. 29,30,34…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Polychlorinated biphenyls (PCBs), a group of chlorinated aromatic hydrocarbons with 209 congeners, have been applied in a wide range of areas including heat transfer fluids and dielectric fluids . However, they are a typical class of the persistent organic pollutants that cause great harm to the environment as well as human health, due to their toxicity, lipophilicity, high stability, and biomagnification through the food chain . It is very urgent to develop a simple, rapid, and efficient method for the determination of PCB residues in water.…”
Section: Introductionmentioning
confidence: 99%
“…The optimization of the SPME-GC/MS method was discussed in another publication (Zhang et al, 2014). Aroclor 1260 standard was used to evaluate the optimization of the SPME and instrument conditions.…”
Section: Resultsmentioning
confidence: 99%
“…Extraction of PCBs from soil samples under optimized conditions were conducted using headspace SPME with 2 mL of saturated potassium dichromate solution and a 100 µm PDMS fiber at 100 °C for 30 min (Zhang et al, 2014). An aliquot of 0.5 g of soil sample was placed in a 20-mL SPME vial with the addition of 20 µL of internal standard solution.…”
Section: Sample Preparationmentioning
confidence: 99%