2005
DOI: 10.1002/jssc.200500062
|View full text |Cite
|
Sign up to set email alerts
|

Determination of bradykinin and arg‐bradykinin in rat muscle tissue by microdialysis and capillary column‐switching liquid chromatography with mass spectrometric detection

Abstract: Quantification of bradykinin peptides in limited amounts of rat muscle tissue dialysate has been performed using a packed capillary LC-ESI-TOF-MS method. The micro dialysate samples (450 microL) with added internal standard were loaded onto a 1 mm x 5 mm loading column packed with 5 microm Kromasil C18 particles by a carrier solution of 0.1% formic acid in ACN/water (5:95, v/v) at a flow rate of 250 microL/min for online preconcentration of the analytes. Back-flushed elution onto a 150 mm x 0.5 mm Zorbax C18 c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
14
0

Year Published

2006
2006
2009
2009

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 24 publications
(15 citation statements)
references
References 19 publications
1
14
0
Order By: Relevance
“…The concentration and mass LODs were l0.1 lg/L (l0.1 nM) and 50 pg, respectively. As expected, the LOD is lower than with UV detection (l1 nM) [7], despite the sample volume was 500 lL [8] versus 1000 lL [7]. The endogenous values obtained in rat dialysates for BD and Arg-BD were 0.1 and 0.4 lg/L, respectively, which are close to their LODs.…”
Section: Ms/ms Detection Setupsupporting
confidence: 63%
See 3 more Smart Citations
“…The concentration and mass LODs were l0.1 lg/L (l0.1 nM) and 50 pg, respectively. As expected, the LOD is lower than with UV detection (l1 nM) [7], despite the sample volume was 500 lL [8] versus 1000 lL [7]. The endogenous values obtained in rat dialysates for BD and Arg-BD were 0.1 and 0.4 lg/L, respectively, which are close to their LODs.…”
Section: Ms/ms Detection Setupsupporting
confidence: 63%
“…Saturation problems are especially important with biological samples, which usually have an abundant and complex background matrix of compounds. the analytes of interest such as microdialysis [8], affinity chromatography [9,10], or precipitation [11][12][13] can be used to circumvent saturation problems. The microdialysis technique allows the continuous sampling of substances from the interstitial space by inserting in the animal tissue a probe with a dialysis membrane, which is constantly perfused with a physiological solution.…”
Section: Ms/ms Detection Setupmentioning
confidence: 99%
See 2 more Smart Citations
“…In cLC, large volumes can be injected using column-switching methods based on focusing on a trap column with subsequent transfer to an analytical column, thus improving the sensitivity [20,21]. Columnswitching systems can also be advantageously used for online sample preparation, which minimizes analysis time, sample loss, and errors due to several preparation steps [22,23].…”
Section: Introductionmentioning
confidence: 99%