2011
DOI: 10.1016/j.talanta.2011.04.050
|View full text |Cite
|
Sign up to set email alerts
|

Determination of cadmium and lead in beverages after leaching from pewter cups using graphite furnace atomic absorption spectrometry

Abstract: Two simple methods have been developed to determine cadmium and lead in different kinds of beverages and vinegar leached from pewter cups produced in Brazil. Leaching experiments have been carried out with different solutions: beer, sugar cane spirit, red and white wine, vinegar and a 3% acetic acid solution. The solutions were kept in cups with and without solder for 24h. Lead and cadmium have been determined using graphite furnace atomic absorption spectrometry with deuterium background correction. The limit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
27
2

Year Published

2012
2012
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(29 citation statements)
references
References 19 publications
0
27
2
Order By: Relevance
“…Concentrations of individual elements are quite often measured in distilled spirits using graphite-furnace atomic absorption spectrometry (GF-AAS) with graphite tubes and integrated or inserted L'vov platforms [1,4,6,11,17,19,34,37,38,45,[49][50][51][52]. Graphite tubes without platforms are rarely used [18,31,45].…”
Section: Methods Of Choice For Elemental Analysis Of Spirit Productsmentioning
confidence: 99%
See 1 more Smart Citation
“…Concentrations of individual elements are quite often measured in distilled spirits using graphite-furnace atomic absorption spectrometry (GF-AAS) with graphite tubes and integrated or inserted L'vov platforms [1,4,6,11,17,19,34,37,38,45,[49][50][51][52]. Graphite tubes without platforms are rarely used [18,31,45].…”
Section: Methods Of Choice For Elemental Analysis Of Spirit Productsmentioning
confidence: 99%
“…Graphite tubes without platforms are rarely used [18,31,45]. GF-AAS is applied to determine a specific group of trace elements {i.e., Al [17,19,34,46], As [1,6,19,37], Cd [11,17,19,20,38,45,46,49,50], Cr [11,18,31,45], Cu [1,6,9,37,50], Fe [52], Ni [9,11,31,45], Pb [1,4,6,9,14,16,17,19,33,37,46,[49][50][51] and Sb [18]}. However, it can also be used for determining selected major and minor elements (i.e., Zn, Fe, Ca, Mg and Na) …”
Section: Methods Of Choice For Elemental Analysis Of Spirit Productsmentioning
confidence: 99%
“…Recently, the cadmium levels of different beverages with and without alcohol by different detection techniques (stripping chronopotenti-ometry, ICP-MS, ICP-OES, TF-FAAS, derivative potentiometric stripping analysis, GF-AAS, flow injection-diode array detection-spectrophotometry, a novel liquid-phase microextraction coupled with FAAS, HG-AFS and ET-AAS) are investigated in detail. Flame atomic absorption spectrometry [Xiang et al, 2012], inductively coupled plasma-optical emission spectrometry [Marchisio et al, 2005;Lara et al, 2001], inductively coupled plasma mass spectrometry [Wu & Boyle, 1997], stripping chronopotentiometry [Lo Coco et al, 2006], derivative potentiometric stripping analysis [La Pera et al, 2003], graphite furnace atomic absorption spectrometry [Schiavo et al, 2008;Ajtony et al, 2008;Dessuy et al, 2011], a novel liquid-phase microextraction coupled with flame atomic absorption spectrometry [Wu et al, 2011], a sequential injection hydride generation atomic fluorescence spectrometry [Duan et al, 2005], and electrothermal atomic absorption spectrometry [Farinas et al, 2007;Jurado et al, 2007] have also been applied for the determination of cadmium in different beverages and food samples. Although some of these techniques are sophisticated and have a high detection power, but they are relatively expensive, time-consuming, need experienced user in its area and not available in all laboratories.…”
Section: Introductionmentioning
confidence: 99%
“…Several authors have used this system in sample digestion process [38][39][40][41][42][43][44][45][46][47].…”
Section: Applications Of Cold Finger System In Sample Preparation Promentioning
confidence: 99%
“…The digestion procedure employed nitric acid and hydrogen peroxide and heating under reflux using cold finger [43].…”
Section: Applications Of Cold Finger System In Sample Preparation Promentioning
confidence: 99%