2018
DOI: 10.1016/j.jelechem.2018.01.014
|View full text |Cite
|
Sign up to set email alerts
|

Determination of cadmium(II) using a glassy carbon electrode modified with a Cd-ion imprinted polymer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
25
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 42 publications
(25 citation statements)
references
References 24 publications
0
25
0
Order By: Relevance
“…pH values above 6.0 can decrease the electrode signal noticeably, as Cd(II) ions would precipitate as hydroxide sediments. 19 All experiments were performed at room temperature. Square wave voltammetry measurements were performed using a preconcentration time of 120 s at −1.3 V, followed by a potential stripping from −1.3 to −0.4 V, with a frequency of 25 Hz.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…pH values above 6.0 can decrease the electrode signal noticeably, as Cd(II) ions would precipitate as hydroxide sediments. 19 All experiments were performed at room temperature. Square wave voltammetry measurements were performed using a preconcentration time of 120 s at −1.3 V, followed by a potential stripping from −1.3 to −0.4 V, with a frequency of 25 Hz.…”
Section: Methodsmentioning
confidence: 99%
“…The detection can be carried out by using mainly anodic stripping voltammetry with different modified electrodes: carbon paste electrodes modified with zirconium-phosphated silica, 1 diacetyldioxime, 2 zeolites, 3,4 carbon nanotubes, 5 conducting polymers, 6 and so forth; bismuth-modified carbon electrodes; 713 silica-modified electrodes; 1417 and many others. 18,19…”
Section: Introductionmentioning
confidence: 99%
“…The latter's use is restricted due to high mercury toxicity concerns (Lu et al, 2018). In the last years the focus of the research community has been on the modification of the GCE using among others nanomaterials, organic molecules and biomolecules (Bansod et al, 2017;Cui et al, 2015;Lee et al, 2016;Zinoubi et al, 2017;Dahaghin et al, 2018;Sadok and Tyszczuk-Rotko, 2018;Lee et al, 2015;Ariño et al, 2017). Film electrodes, in situ or ex situ prepared with mainly bismuth, but also of copper, lead and tin, have been also explored (Ariño et al, 2017;Jovanovski et al, 2015Jovanovski et al, , 2017Economou, 2005;Petovar et al, 2018;Czop, 2011;Korolczuk et al, 2005).…”
Section: Introductionmentioning
confidence: 99%
“…19 Imprinted polymer nanoparticles were synthesized by polymerization of 4-vinylpyridine, EGDMA, 2,2'-azobisisobutyronitrile, 2-aminobenzimidazole, and Cd II , in acetonitrile medium. 20 IIP-Cd II was hydrothermally synthesized by the use of silica gel, methanesulfonic acid, and 3-mercaptopropyltrimethoxysilane. 21 Cd II -imprinted sorbent with interpenetrating polymer network (IPN) has been applied to the determination of Cd II ions in water samples.…”
Section: Introductionmentioning
confidence: 99%