2001
DOI: 10.1039/b106974h
|View full text |Cite
|
Sign up to set email alerts
|

Determination of cadmium in sediment by isotope dilution inductively coupled plasma mass spectrometry using a co-precipitation separation technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
22
0

Year Published

2002
2002
2013
2013

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 30 publications
(22 citation statements)
references
References 15 publications
0
22
0
Order By: Relevance
“…The procedure for ID measurement was almost identical with those described in previous papers [2,4]. The measured isotope pairs in the ID measurement were 52 Cr/ 53 Cr, 60 Hg were also measured to determine the isotopic abundance ratio of Pb in the sample and the standard solution used for the reverse-ID procedure.…”
Section: Isotope Dilution Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The procedure for ID measurement was almost identical with those described in previous papers [2,4]. The measured isotope pairs in the ID measurement were 52 Cr/ 53 Cr, 60 Hg were also measured to determine the isotopic abundance ratio of Pb in the sample and the standard solution used for the reverse-ID procedure.…”
Section: Isotope Dilution Methodsmentioning
confidence: 99%
“…The digestion procedure for most elements except for Cr and Hg have been described in previous papers [2,3,4]. In brief, the sample (ca.…”
Section: Chemicalsmentioning
confidence: 99%
“…1 Inductively coupled plasma-mass spectrometry (ICP-MS) can detect Cd at levels of nanograms per liter; 2 however, mass spectral interference by molybdenum oxide (MoO) generated in a hot plasma has been observed in both sediment analysis 3 and biological samples. 4,5 Molybdenum (Mo) is an essential element for nutrition, and enters the human body primarily in the diet with an average dietary daily intake of approximately 100 mg day -1 .…”
Section: Introductionmentioning
confidence: 99%
“…2 Interferences caused by coexisting compounds in samples can be avoided by sample pretreatment in which the interfering compounds are removed by, for example, coprecipitation or ion-exchange. [3][4][5] Uses of a desolvation apparatus for sample introduction, of a low-temperature plasma, and a high-resolution mass spectrometer are effective ways of reducing and removing interferences. [6][7][8][9][10][11] In recent years, methods employing collision/reaction gas cells using He, H2, NH3, CH4, or O2 have been introduced into ICP-MS to remove the interferences of coexisting ions.…”
Section: Introductionmentioning
confidence: 99%