2006
DOI: 10.1016/j.bios.2005.10.013
|View full text |Cite
|
Sign up to set email alerts
|

Determination of carbaryl in natural water samples by a surface plasmon resonance flow-through immunosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
47
0
1

Year Published

2009
2009
2021
2021

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 126 publications
(48 citation statements)
references
References 17 publications
0
47
0
1
Order By: Relevance
“…They produce rapid and reliable results with minimal sample preparation and use of analyte (Elliott et al, 1999;Gaudin et al, 2001;Gustavsson et al, 2002;Haasnoot et al, 2002;Mello and Kubota, 2002;Samsonova et al, 2002;Ferguson et al, 2002Ferguson et al, , 2005Gaudin et al, 2005;Traynor et al, 2006;Mauriz et al, 2006;Llamas et al, 2007;Campbell et al, 2007;Connolly et al, 2007, Campas et al, 2007. This technology allows for real time, automated analysis combining the high affinity of biochemical interactions with low limits of detection and is characterised by its simplicity of use.…”
Section: Introductionmentioning
confidence: 99%
“…They produce rapid and reliable results with minimal sample preparation and use of analyte (Elliott et al, 1999;Gaudin et al, 2001;Gustavsson et al, 2002;Haasnoot et al, 2002;Mello and Kubota, 2002;Samsonova et al, 2002;Ferguson et al, 2002Ferguson et al, , 2005Gaudin et al, 2005;Traynor et al, 2006;Mauriz et al, 2006;Llamas et al, 2007;Campbell et al, 2007;Connolly et al, 2007, Campas et al, 2007. This technology allows for real time, automated analysis combining the high affinity of biochemical interactions with low limits of detection and is characterised by its simplicity of use.…”
Section: Introductionmentioning
confidence: 99%
“…[37][38][39][40][41][42][43][44][45][46] This labelfree, automated analysis technique combines the high affinity of biochemical interactions with low limits of detection producing rapid and reliable results. Minimal amounts of analyte are required to produce the chip surfaces, and these surfaces can be reused many times without loss of activity.…”
mentioning
confidence: 99%
“…Taking advantage of QCM measurements based on the phase/mass approach above described, in the present work we report the development of an HFF-QCM immunosensor for the highsensitivity determination of carbaryl and thiabendazole pesticides. Carbaryl, the first successful carbamate insecticide with a broad-spectrum efficacy, was chosen as a model analyte because it has become a reference analyte for immunoassay comparison, from ELISA to immunosensors March et al, 2009;Mauriz et al, 2006).…”
Section: Introductionmentioning
confidence: 99%