Determination of carboxylic acids in non-alcoholic beer samples by an ultrasonic-assisted dispersive micro-solid phase extraction based on Ni/Cu-Al layered double hydroxide nanocomposites followed by gas chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(3 citation statements)
references
References 39 publications
0
3
0
Order By: Relevance
“…Many studies have been published on applying SPE to beverage analysis. Most of them focus on the quantification of a certain group of VOCs [104][105][106], and the HS-SPE application was also used to obtain extracts with a composition closer to the orthonasal olfaction process [107]. An exciting variety of SPE uses small particles made of nanomaterials for liquid samples.…”
Section: Solid-phase Extractionmentioning
confidence: 99%
“…Many studies have been published on applying SPE to beverage analysis. Most of them focus on the quantification of a certain group of VOCs [104][105][106], and the HS-SPE application was also used to obtain extracts with a composition closer to the orthonasal olfaction process [107]. An exciting variety of SPE uses small particles made of nanomaterials for liquid samples.…”
Section: Solid-phase Extractionmentioning
confidence: 99%
“…So, the optimum pH was found to be 6.0, since the removal percentage reached the maximum level at this pH value, given the fact that at acidic pH, LDH and Fe 3 O 4 @SiO 2 were dissolved and the structure of sorbent was destroyed. In addition, in the solution with higher pHs, the hydroxide precipitate of As (V) ions was formed and competition between OH − and As (V) ions for the adsorption on the surface of the sorbent occurred (15,38). Considering the pH-dependent behavior of AS adsorption on the synthesized sorbent, the adsorption process seemed to be controlled by different factors, such as electrostatic interactions and surface adsorption.…”
Section: Optimization Of Removal Conditionsmentioning
confidence: 99%
“…In this case, the magnetic sorbent was prepared by the coprecipitation of the desired LDH on already preformed nanoscale zero‐valent iron, and applied to the extraction of naphthols before HPLC analysis. Magnetic Ni/CuAl‐LDH nanocomposites were also evaluated as sorbents for ultrasound‐assisted D‐μ‐SPE of carboxylic acids from nonalcoholic beer samples . In this case, analytes were desorbed using acetonitrile and quantified by GC–FID.…”
Section: Layered Double Hydroxidesmentioning