2000
DOI: 10.1016/s0021-9673(99)01317-5
|View full text |Cite
|
Sign up to set email alerts
|

Determination of cephalosporins in raw bovine milk by high-performance liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
52
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 83 publications
(55 citation statements)
references
References 6 publications
0
52
0
Order By: Relevance
“…However, a number of methods for the determination of cefquinome were reported for milk and animal tissues. These methods include high-performance liquid chromatography with UV detector (HPLC-UV) (17,18,21), HPLC with diode array detector (5), liquid chromatography combined with tandem mass spectrometry (1), and screening methods (7,8,13,14,18). To the authors' knowledge, only two published papers involving analytical methods for the determination of cefquinome in plasma, one employing liquid chromatography combined with electrospray tandem mass spectrometry (LC-ESI-MS-MS) (11) and one using HPLC-UV (9), reported complete validation procedures.…”
mentioning
confidence: 99%
“…However, a number of methods for the determination of cefquinome were reported for milk and animal tissues. These methods include high-performance liquid chromatography with UV detector (HPLC-UV) (17,18,21), HPLC with diode array detector (5), liquid chromatography combined with tandem mass spectrometry (1), and screening methods (7,8,13,14,18). To the authors' knowledge, only two published papers involving analytical methods for the determination of cefquinome in plasma, one employing liquid chromatography combined with electrospray tandem mass spectrometry (LC-ESI-MS-MS) (11) and one using HPLC-UV (9), reported complete validation procedures.…”
mentioning
confidence: 99%
“…Determination of CEZ concentration in the manure and seed sludge sample was carried out with HPLC [12] after solid phase extraction (SPE) of a sample using a modified method described by Sørensen et al [13]. A diluted sample was centrifuged and supernatant was loaded to a tC18 SPE cartridge (Sep-Pak tC18, Waters, Milford, MA, USA).…”
Section: Analytical Methods Of Cezmentioning
confidence: 99%
“…Octadecyl (C18)-bonded silica is the most widely employed SPE sorbent [37][38][39][40], although other solid phase materials such as LiChrolut EN [41], Isolut ENV1 [42,43] and even weak cation- [3], and strong anionexchangers [44] have also been reported in the literature for this purpose. The elution of the antibiotics retained by these sorbents is usually performed with aqueous methanol or ACN in some cases modified with a buffer.…”
Section: Factors Affecting Spe Preconcentration Of â-Lactam Antibioticsmentioning
confidence: 99%