2019
DOI: 10.15583/jpchrom.2019.011
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Chiral Amino Acids in Various Fermented Products Using a Two-Dimensional HPLC-MS/MS System

Abstract: Chiral amino acids in fermented products including Japanese traditional black vinegar, a processed cheese and nam pla were determined using an on-line two-dimensional (2D) HPLC-MS/MS system. As the target amino acids, Ala, Asp, Glu, Leu, Pro and Ser were selected. Prior to the HPLC separation, the fermented products were appropriately homogenized and deproteinized, then amino acids were derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F). Using the 2D-HPLC system, the target NBD-amino acids were ind… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 21 publications
(10 citation statements)
references
References 31 publications
1
9
0
Order By: Relevance
“…Without using chiral reagents, a UPLC method equipped with a circular dichroism detector [30] and a chiral HPLC-MS/MS system [31] have been used for the analysis of all the proteinogenic amino acids in the vinegar samples. To perform a higher selective analysis, a two-dimensional (2D) HPLC system combining reversed-phase and enantioselective columns [32,33] and a 2D-HPLC-MS/MS system [34] have been developed and clarified the developmental changes of the D-amino acid concentrations during the fermentation processes. By using these analytical methods, the %D values of Asp, Ser and Ala in the rice vinegar samples were reported to be 1.3-35.3, 0.9-21.6 and 1.1-38.3, respectively [28][29][30]32,34].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Without using chiral reagents, a UPLC method equipped with a circular dichroism detector [30] and a chiral HPLC-MS/MS system [31] have been used for the analysis of all the proteinogenic amino acids in the vinegar samples. To perform a higher selective analysis, a two-dimensional (2D) HPLC system combining reversed-phase and enantioselective columns [32,33] and a 2D-HPLC-MS/MS system [34] have been developed and clarified the developmental changes of the D-amino acid concentrations during the fermentation processes. By using these analytical methods, the %D values of Asp, Ser and Ala in the rice vinegar samples were reported to be 1.3-35.3, 0.9-21.6 and 1.1-38.3, respectively [28][29][30]32,34].…”
Section: Resultsmentioning
confidence: 99%
“…To perform a higher selective analysis, a two-dimensional (2D) HPLC system combining reversed-phase and enantioselective columns [32,33] and a 2D-HPLC-MS/MS system [34] have been developed and clarified the developmental changes of the D-amino acid concentrations during the fermentation processes. By using these analytical methods, the %D values of Asp, Ser and Ala in the rice vinegar samples were reported to be 1.3-35.3, 0.9-21.6 and 1.1-38.3, respectively [28][29][30]32,34]. The D-amino acid amounts in the traditionally fermented rice vinegars seem to be higher than those in the other rice vinegars.…”
Section: Resultsmentioning
confidence: 99%
“…In foodstuffs and beverages, relatively high levels of D-amino acids are considered to be contained particularly in the fermented products due to the generation by microorganisms. Accordingly, the commercially available fermented foods/beverages including processed cheese, Japanese traditional black vinegar (amber rice vinegar) and nam pla (fish source) are selected and the chiral amino acids in these foodstuffs are analyzed by the 2D HPLC-MS/MS system [53]. The chromatograms obtained using the black vinegar are shown in Fig.…”
Section: D Hplc-ms/ms Analysis Of Chiral Amino Acidsmentioning
confidence: 99%
“…Liquid chromatography (LC) is one of the most powerful separation techniques for various types of complex mixtures and it has been employed in a wide range of scientific fields such as pharmaceutical, analytical and environmental chemistry [1][2][3][4][5]. In order to make sure an effective LC separation of real samples commonly encountered, a suitable setting of the separation conditions, especially, the choice of an appropriate stationary phase is quite important parameter [6][7][8][9][10].…”
Section: Introductionmentioning
confidence: 99%