2013
DOI: 10.1016/j.talanta.2012.10.031
|View full text |Cite
|
Sign up to set email alerts
|

Determination of chromium in estuarine waters by catalytic cathodic stripping voltammetry using a vibrating silver amalgam microwire electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 24 publications
0
9
0
Order By: Relevance
“…The calculation performed based on ten analyses carried out for 1 nmol• Comparing the presented sensor to other electrochemical sensors designated for Cr(VI) determination (see Table 3), it can be noticed that in this case, linear response range was better than obtained for the sensors based on hybrid films of phosphate cellulose and electroactive polymer [29], polyaniline/graphene quantum dot-modified screen-printed carbon electrode [31] and screen-printed carbon electrode modified with gold nanoparticles [32]. The developed sensor exhibited lower limit of detection in comparison with all reported sensors except for vibrating silver amalgam microwire electrode demonstrating similar LOD values [30].…”
Section: Verification Of Sensor Functioningmentioning
confidence: 61%
See 1 more Smart Citation
“…The calculation performed based on ten analyses carried out for 1 nmol• Comparing the presented sensor to other electrochemical sensors designated for Cr(VI) determination (see Table 3), it can be noticed that in this case, linear response range was better than obtained for the sensors based on hybrid films of phosphate cellulose and electroactive polymer [29], polyaniline/graphene quantum dot-modified screen-printed carbon electrode [31] and screen-printed carbon electrode modified with gold nanoparticles [32]. The developed sensor exhibited lower limit of detection in comparison with all reported sensors except for vibrating silver amalgam microwire electrode demonstrating similar LOD values [30].…”
Section: Verification Of Sensor Functioningmentioning
confidence: 61%
“…The second form, Cr(VI), has an undesirable effect on the lungs, liver, and kidneys. The examples of electrochemical chromium(VI) determination include the use of a glassy carbon electrode modified with silicomolybdate doped polypyrrole film [28], the preparation of hybrid and electroactive thin films containing microcrystalline cellulose (MC), or MC modified with a phosphate group (PC) in conjunction with polyaniline (PANI) and poly(vinyl sulfonic acid) (PVS) by the layer-by-layer technique [29] or determination in estuarine waters by catalytic cathodic stripping voltammetry using a vibrating silver amalgam microwire electrode [30]. The determination of Cr(VI) employing the screen-printed carbon electrode (SPCE) modified with the use of organic compound (PANI) and graphene quantum dot [31] or inorganic nanoparticles like AuNPs [32] have been reported.…”
Section: Introductionmentioning
confidence: 99%
“…Mercury based electrodes [13,14,21,22] were commonly used for the AdCSV determination of Cr(VI) but due to mercury toxicity different electrode materials like bismuth [16,19] or carbon [8,10] were proposed for Cr(VI) determination.…”
Section: Introductionmentioning
confidence: 99%
“…Platinum microwire electrodes have been widely studied and employed, for example, in sensing . The diffusion to mirowire electrodes is cylindrical and rapidly approaches quasi‐steady state , which helps in stabilising sensor responses.…”
Section: Introductionmentioning
confidence: 99%
“…Platinumm icrowire electrodes have been widely studied [10][11][12] and employed, for example,i ns ensing [ 13]. Thed iffusion to mirowire electrodes is cylindrical and rapidly approaches quasi-steady state [14],w hich helps in stabilising sensor responses.H ence, the application of microwires as fuel cell electrodes has potential benefits in terms of stability of power outputa nd has been em-ployed, for example, in PtCu alloye lectrocatalystt esting [15].Inthis report, we presentarapid methodofcleaning and annealing commercial platinum microwires using electrothermal treatment.…”
mentioning
confidence: 99%