2006
DOI: 10.1016/j.aca.2006.02.046
|View full text |Cite
|
Sign up to set email alerts
|

Determination of chromium, iron and selenium in foodstuffs of animal origin by collision cell technology, inductively coupled plasma mass spectrometry (ICP-MS), after closed vessel microwave digestion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
39
0
1

Year Published

2007
2007
2017
2017

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 52 publications
(42 citation statements)
references
References 29 publications
2
39
0
1
Order By: Relevance
“…During the determination of trace elements, including chromium in foodstuffs of animal origin, satisfactory results were reported using H 2 and He gases in collision cell technology (CCT) mode. 30 Other studies employing CCT systems demonstrated the effectiveness of H 2 and He gases, in terms of reduction of the argon-based interferences and limits of detection. 31,32 Reactive gases such as NH 3 and CH 4 were tested on DRC mode, for quantification of chromium in food, biological fluids and environmental samples.…”
Section: Selection Of Drc-icp-ms Conditionsmentioning
confidence: 99%
“…During the determination of trace elements, including chromium in foodstuffs of animal origin, satisfactory results were reported using H 2 and He gases in collision cell technology (CCT) mode. 30 Other studies employing CCT systems demonstrated the effectiveness of H 2 and He gases, in terms of reduction of the argon-based interferences and limits of detection. 31,32 Reactive gases such as NH 3 and CH 4 were tested on DRC mode, for quantification of chromium in food, biological fluids and environmental samples.…”
Section: Selection Of Drc-icp-ms Conditionsmentioning
confidence: 99%
“…Se in the blood or liver was determined by ICP-MS assay. 34 Moreover, liver samples were homogenized in ice-cold saline and centrifuged at 12,000× g at 4°C for 15 minutes. The resulting supernatants and the plasma samples were used to determine the levels of TBARS, GSH, CAT, SOD, GSH-Px and total protein, following the instructions of commercial kits.…”
mentioning
confidence: 99%
“…As illustrated in Scheme 1A, CTSSeNPs were spray-dried, and SeNPs were finally embedded into solid SeNPs-M. White Blank-M (without any Se) and red SeNPs-M were obtained, both of which were free-flowing powders. The Se content of SeNPs-M was determined by ICP-MS, 34 and it could be adjusted by modifying the material ratio. An SeNPs-M sample (29 g Se/kg) was selected to conduct the rest of the study.…”
mentioning
confidence: 99%
“…In discussion of Cr analysis, it is important to discuss ICP-MS techniques [3,4,9,10]. The new ICP-MS instruments give LODs as low as 0.18 [3] and 0.11 ng/ml [9], which are similar to that of the present ESI-MS-MS method.…”
Section: Resultsmentioning
confidence: 52%
“…This cannot be avoided even if collision cell technology, which is similar to the MS-MS system, is used [10]. Therefore, ICP-MS cannot be used for hematuric urine samples, in which Fe ions derived from hemoglobin are abundant.…”
Section: Resultsmentioning
confidence: 96%