2009
DOI: 10.2106/jbjs.h.01161
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Correct Implant Size in Radial Head Arthroplasty to Avoid Overlengthening

Abstract: Incongruity of the medial ulnohumeral joint becomes apparent radiographically only after overlengthening of the radius by >or=6 mm. Intraoperative visualization of a gap in the lateral ulnohumeral joint is a reliable indicator of overlengthening following the insertion of a radial head prosthesis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
34
0
3

Year Published

2012
2012
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 99 publications
(38 citation statements)
references
References 20 publications
1
34
0
3
Order By: Relevance
“…Van Glabbeek et al [23] also showed how overstuffing the radiocapitellar joint by even 2.5 mm resulted in increased joint pressures. Frank et al [6] reported that intraoperative visualization of a gap in the medial ulnohumeral joint may indicate overstuffing. Doornberg et al [3] recommended sizing the radial head so that it was even with the articular surface of the coronoid, and we have found better results using this guideline.…”
Section: Discussionmentioning
confidence: 99%
“…Van Glabbeek et al [23] also showed how overstuffing the radiocapitellar joint by even 2.5 mm resulted in increased joint pressures. Frank et al [6] reported that intraoperative visualization of a gap in the medial ulnohumeral joint may indicate overstuffing. Doornberg et al [3] recommended sizing the radial head so that it was even with the articular surface of the coronoid, and we have found better results using this guideline.…”
Section: Discussionmentioning
confidence: 99%
“…The failure to select an implant that best approximates the native radial head dimensions leads to an alteration in joint architecture and mechanics, which may lead to poor clinical and radiologic outcomes. 4,8,11,13 There are a number of published techniques that describe methods to determine radial head implant height, 2,6 but there is a paucity of information that addresses the manner in which the diameter of the native radial head should be measured. To our knowledge, there is one published article that looks at measuring the 3 common diameters (D-MAX, D-MIN, D-DISH) as we have done in this study.…”
Section: Discussionmentioning
confidence: 99%
“…The failure to appropriately size the radial head prosthesis (and, in particular, oversizing of the radial head) leads to an alteration in joint architecture and mechanics that results in restricted elbow motion, capitellar erosion, pain, and earlyonset osteoarthritis. 4,6,8,11,13 To prevent overlengthening or ''overstuffing'' of the implant, a number of techniques have been described to size the height of the radial head. 2,3,6,8 None of these studies, however, have reported on techniques to reliably choose the correct radial head diameter.…”
mentioning
confidence: 99%
“…The remaining ossifications (n=5) were located in the ventral aspect of the elbow and could be classified as grade 1 [11]. There was no implant loosening, no bone resorption and no evident radiocapitellar overstuffing [9].…”
Section: Entire Cohortmentioning