2016
DOI: 10.1016/j.chroma.2016.11.055
|View full text |Cite
|
Sign up to set email alerts
|

Determination of diamondoids in crude oils using gas purge microsyringe extraction with comprehensive two dimensional gas chromatography-time-of-flight mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 35 publications
0
4
0
Order By: Relevance
“…Crude oils were dissolved in n -hexane (100 mg mL −1 ) and spiked with 11 PA standards ( Table 1 ) at a certain concentration (100 ng mL −1 ) to study the extraction efficiency under different conditions. To obtain a blank sample for calibration and validation purposes, a crude oil was fractionated into saturates, aromatics, resins and asphaltenes (SARA fractionation method), 30 and then the saturates, aromatics and asphaltenes fractions were remixed together as the matrix free of PAs.…”
Section: Methodsmentioning
confidence: 99%
“…Crude oils were dissolved in n -hexane (100 mg mL −1 ) and spiked with 11 PA standards ( Table 1 ) at a certain concentration (100 ng mL −1 ) to study the extraction efficiency under different conditions. To obtain a blank sample for calibration and validation purposes, a crude oil was fractionated into saturates, aromatics, resins and asphaltenes (SARA fractionation method), 30 and then the saturates, aromatics and asphaltenes fractions were remixed together as the matrix free of PAs.…”
Section: Methodsmentioning
confidence: 99%
“…Zhu et al 21 proposed a gas purge microsyringe extraction (GP-MSE) device, which was combined with GC−MS to analyze crude oil samples. 22 The obtained data were analyzed by multivariate statistical analysis. It was found that light hydrocarbons can be used as alternatives to conventional biomarkers, 23 and a method for indicating the direction of oil migration by the content of dimethyldibenzothiophene compounds was proposed.…”
Section: Introductionmentioning
confidence: 99%
“…Similarly, Zhang et al employed GC × GC/TOF MS and PCA to differentiate oil sources and identified a series of triaromatic steroid compounds as suitable marker compounds for crude oil screening. Zhu et al proposed a gas purge microsyringe extraction (GP-MSE) device, which was combined with GC–MS to analyze crude oil samples . The obtained data were analyzed by multivariate statistical analysis.…”
Section: Introductionmentioning
confidence: 99%
“…4,5 In our group, gas purge microsyringe extraction (GP-MSE) and micro-solid phase extraction based on a glass pipette have been developed recently and shows some outstanding advantages, but needs to couple other sample pretreatment steps when analyzing water samples. [6][7][8][9] Magnetic solid phase extraction (MSPE), developed from SPE, has drawn great attention for its advantages of extraction efficiency and material reuse. [10][11][12][13][14] Magnetic or magnetizable adsorbents can be dispersed in sample matrix for preconcentration of target analytes, and isolated from matrix by using an external magnet.…”
Section: Introductionmentioning
confidence: 99%