2009
DOI: 10.1021/ac901380v
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Elemental Constituents in Different Matrix Materials and Flow Injection Studies by the Electrolyte Cathode Glow Discharge Technique with a New Design

Abstract: An open-to-air type electrolyte cathode discharge (ELCAD) has been developed with a new design. The present configuration leads to a stable plasma even at low flow rates (0.96 mL/min). Plasma fluctuations arising from the variations in the gap between solid anode and liquid cathode were eliminated by providing a V-groove to the liquid glass-capillary. Cathode (ground) connection is given to the solution at the V-groove itself. Interfaced to atomic emission spectrometry (AES), its analytical performance is eval… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

6
74
1

Year Published

2011
2011
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 79 publications
(81 citation statements)
references
References 36 publications
6
74
1
Order By: Relevance
“…They sheared a considerable interest and are the subject of a growing number of works [1][2][3]. Among developed and studied in recent years miniaturized excitation sources there are dielectric barrier discharge (DBD), electrolyte as cathode glow discharge (ELCAD), liquid sampling atmospheric pressure glow discharge (LS-APGD), solution cathode glow discharge (SCGD), capacitively coupled plasma (CCP) and microstrip plasma (MSP) [4][5][6][7][8][9][10][11][12][13][14][15][16][17][18]. In general, these new excitation sources enable efficient excitation of elements with relatively low excitation potentials, i.e., alkali and alkaline earth elements and some of transition metals.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…They sheared a considerable interest and are the subject of a growing number of works [1][2][3]. Among developed and studied in recent years miniaturized excitation sources there are dielectric barrier discharge (DBD), electrolyte as cathode glow discharge (ELCAD), liquid sampling atmospheric pressure glow discharge (LS-APGD), solution cathode glow discharge (SCGD), capacitively coupled plasma (CCP) and microstrip plasma (MSP) [4][5][6][7][8][9][10][11][12][13][14][15][16][17][18]. In general, these new excitation sources enable efficient excitation of elements with relatively low excitation potentials, i.e., alkali and alkaline earth elements and some of transition metals.…”
Section: Introductionmentioning
confidence: 99%
“…In general, these new excitation sources enable efficient excitation of elements with relatively low excitation potentials, i.e., alkali and alkaline earth elements and some of transition metals. Limits of detection (LODs) of elements usually vary from several to tens micro gram per liter and because of that miniaturized excitation sources are commonly used for their quantification in different samples [4][5][6][7][8][9][10][11][12][13][14][15][16]. On the other hand, mentioned radiation sources are rarely utilized for the determination of elements with high excitation potentials, e.g., As, Sb or Se, with OES.…”
Section: Introductionmentioning
confidence: 99%
“…[7][8][9][10] The values of DLs of alkaline earth metals and transition metals are higher and usually span the range of 1-25 mg L À1 . [7][8][9][10][11][12][13][14] Considering the achievements made in the last 3 years in the application of APGD generated in contact with the liquid cathode as an efficient excitation source for analytical OES, it is evident that much effort has been devoted to improving the DL of Hg. This element is usually present in food and water samples at very low concentrations.…”
Section: Introductionmentioning
confidence: 99%
“…Changes in the design of electrolyte solution delivery capillaries made in last several years led to the improvement of the optical thinness of the discharge and its stability [4,[10][11][12][13][16][17][18][19][20][21]. A better reproducibility of the discharge gap results in a much better analytical performance of such modified discharge systems.…”
Section: Introductionmentioning
confidence: 99%
“…Linearity ranges reported for these systems typically vary from 2 to at least 4 orders of the concentration, while the precision in most cases is better than 6%. All these improved figures of merit make dc-APGD generated in contact with the liquid cathode a highly desirable instrumental method for the spectrochemical analysis of food samples, including tap, drinking and mineral waters [4,7], tea infusion [4], tea leaves [4], fresh milk [7], tuna fish [20][21][22], oyster tissue [20] or aquatic plant [22].…”
Section: Introductionmentioning
confidence: 99%