Determination of emerging contaminants in wastewater utilizing comprehensive two-dimensional gas-chromatography coupled with time-of-flight mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
40
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 47 publications
(40 citation statements)
references
References 23 publications
0
40
0
Order By: Relevance
“…Some studies have reported non-targeted screening for EOCs by gas chromatography (Slobodnik et al 2012) and liquid chromatography (Hernández et al 2014). Comprehensive two-dimensional gas chromatography -time-of-flight mass spectrometry (GC×GC-TOFMS) has also been recently utilized to enable automated comparison of environmental samples and blanks to identify EOCs as outliers of the normal sample matrix (Prebihalo et al 2015). Non-targeted analysis has previously been carried out in Finland by Nurmi et al 2012and Jernberg et al (2013a, 2013b.…”
Section: Introductionmentioning
confidence: 99%
“…Some studies have reported non-targeted screening for EOCs by gas chromatography (Slobodnik et al 2012) and liquid chromatography (Hernández et al 2014). Comprehensive two-dimensional gas chromatography -time-of-flight mass spectrometry (GC×GC-TOFMS) has also been recently utilized to enable automated comparison of environmental samples and blanks to identify EOCs as outliers of the normal sample matrix (Prebihalo et al 2015). Non-targeted analysis has previously been carried out in Finland by Nurmi et al 2012and Jernberg et al (2013a, 2013b.…”
Section: Introductionmentioning
confidence: 99%
“…This system utilizes a xed quad-jet modulator consisting of two liquid nitrogen jets and two pulsed hot-air jets to trap and refocus compounds eluted from the rst dimension (1D) column. 44 The modulation period was 2.5 s. The hot pulse duration was 0.60 s.…”
Section: Methodsmentioning
confidence: 99%
“…They also reported that compared to commonly used cyanopropylphenyl polysiloxane, the SLB‐IL111 column showed a shorter analysis time for the baseline separation and quantification of nitrosamines. Prebihalo et al used two‐dimensional gas‐chromatography coupled with time‐of‐flight mass spectrometry (GC × GC‐TOFMS) for analyzing ECs in WW. They reported that the analytical technique permitted the identification of halogenated benzotriazoles in WW and the use of the GC × GC‐TOFMS technique proved to be a valuable tool in resolving complex matrices, as it allows the analyst to separate target compounds.…”
Section: Introductionmentioning
confidence: 99%