2002
DOI: 10.2116/analsci.18.525
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Estazolam in Plasma by High-Performance Liquid Chromatography with Solid-Phase Extraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2003
2003
2019
2019

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…Samples were drawn every 20 min from 1200 to 1500 h and again at 1600 h via intravenous catheter placed in a forearm vein at 0900 h. Blood samples were immediately centrifuged at 3000 rpm for 5 min, and the plasma was collected and frozen at À201C for later assay. Plasma concentrations of DZP and dmDZP were determined according to a high-performance liquid chromatography (HPLC) method previously described (Miura et al, 2002;Nagasaki et al, 1999) but with some modifications. The apparatus used for HPLC was the EP-300 chromatography pump (EICOM, Kyoto, Japan) equipped with an EICOM NOD-10 NOx detector.…”
Section: Methodsmentioning
confidence: 99%
“…Samples were drawn every 20 min from 1200 to 1500 h and again at 1600 h via intravenous catheter placed in a forearm vein at 0900 h. Blood samples were immediately centrifuged at 3000 rpm for 5 min, and the plasma was collected and frozen at À201C for later assay. Plasma concentrations of DZP and dmDZP were determined according to a high-performance liquid chromatography (HPLC) method previously described (Miura et al, 2002;Nagasaki et al, 1999) but with some modifications. The apparatus used for HPLC was the EP-300 chromatography pump (EICOM, Kyoto, Japan) equipped with an EICOM NOD-10 NOx detector.…”
Section: Methodsmentioning
confidence: 99%
“…Samples were drawn every 20 min from 1200 h to 1500 h and again at 1600 h via intravenous catheter placed in a forearm vein at 0900 h. Blood samples were immediately centrifuged at 3000 rpm for 5 min, and the plasma was collected and frozen at À208C for later assay. Plasma concentrations of DZP and dmDZP were determined by high-performance liquid chromatography as previously described (Miura et al, 2002;Nagasaki et al, 1999) but with some modifications. The quantification limit for both DZP and dmDZP was 1 ng/ml.…”
Section: Evaluation Of Plasma Concentrations Of Dzp and Desmethyldiazmentioning
confidence: 99%
“…Benzodiazepine estazolam(EST) is a potent, hypnotic prescription that is often used to treat insomnia. [1][2][3] According to China's national administrative regulations, illegal sales of excessive EST are equivalent to drug trafficking. Additionally, reports of cases on the use of EST for drug-induced sexual assaults still occur from time to time.…”
Section: Introductionmentioning
confidence: 99%
“…In the previous literature reports, there are many methods for detecting estazolam, such as High-Performance Liquid Chromatography (HPLC), Gas Chromatography (GC), and Liquid Chromatography-Mass Spectrometry (LC-MS). [1][2][3][4][5][6][7] These methods can achieve excellent detection concentrations. However, the pre-conditions such as complicated pre-processing steps, long detection time and the unportable instrument cannot meet the requirements of real-time on-site detection.…”
Section: Introductionmentioning
confidence: 99%