2012
DOI: 10.1051/epjconf/20122501096
|View full text |Cite
|
Sign up to set email alerts
|

Determination of flow rate characteristics for pneumatic valves

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…Based on the patent of the authors, an automatic measurement system (AMS) was developed to measure the leakage flow rate in industrial CAS. The article [19] describes a method for measuring the characteristics of the flow rate of a proportional pressure regulator based on the charge and discharge of the tank through the valve while monitoring the downstream pressure, the upstream pressure, the temperature of the supply air, and the pressure inside the tank. In the work [20], a new discharge method was proposed for the flow characteristics of high-pressure pneumatic servo valves, based on the principle of sonic discharges of series connection orifices.…”
Section: Measurement Methods To Determine the Flow Parameters Of Pneu...mentioning
confidence: 99%
“…Based on the patent of the authors, an automatic measurement system (AMS) was developed to measure the leakage flow rate in industrial CAS. The article [19] describes a method for measuring the characteristics of the flow rate of a proportional pressure regulator based on the charge and discharge of the tank through the valve while monitoring the downstream pressure, the upstream pressure, the temperature of the supply air, and the pressure inside the tank. In the work [20], a new discharge method was proposed for the flow characteristics of high-pressure pneumatic servo valves, based on the principle of sonic discharges of series connection orifices.…”
Section: Measurement Methods To Determine the Flow Parameters Of Pneu...mentioning
confidence: 99%
“…The mathematical model of a pneumatic system is highly non-linear [8], [9], [10], and the numerical simulation is used to determine the capability of the system to perform a given task, in terms of dynamic behavior.…”
Section: The Theoretical Analysis Of the Intelligent Pneumatic Actuatormentioning
confidence: 99%
“…Thus, due to the C and b values that have not been informed by the valve manufacturer, in this work, we consider an alternative procedure for estimating these parameters. Such procedure is based on charging and discharging a constant volume tank through the valve evaluated at isothermal conditions [34,35]. In agreement with the state equation of ideal gases [17], the pressure variation at the valve downstream connected to a pneumatic load can be expressed as where ṗ out is the valve output pressure derivative (bar/s); κ is the conversion factor; R is the gas ideal constant = 286,9 (J/Kg °K); V is the container volume (m 3 ); and V is the container volume derivative (m 3 /s).…”
Section: Appendixmentioning
confidence: 99%
“…The first parameter was obtained from ( 13) and the second one, as the point where the derivative of the valve output pressure signal changes. Of note is that b value expresses the divide of the valve downstream and upstream absolute pressure for which the flow rate through it becomes choked [17,34,35]. Besides, the effect of the flow-rate disturbance on PPRV outlet absolute pressure was modelled according to (1) and (2) and using the C and b values previously estimated.…”
Section: Appendixmentioning
confidence: 99%