Determination of gas-temperature and velocity profiles in an argon thermal-plasma jet by laser-light scattering

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

1993
1993
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 51 publications
(17 citation statements)
references
References 18 publications
0
17
0
Order By: Relevance
“…Generally they can be divided as based on emission spectroscopy [12], laser absorption spectroscopy [12][13][14][15] and laser scattering [16]. In case of emission spectroscopy the T a can for instance be obtained from the rotational temperature of excited molecular species.…”
Section: Introductionmentioning
confidence: 99%
“…Generally they can be divided as based on emission spectroscopy [12], laser absorption spectroscopy [12][13][14][15] and laser scattering [16]. In case of emission spectroscopy the T a can for instance be obtained from the rotational temperature of excited molecular species.…”
Section: Introductionmentioning
confidence: 99%
“…In Figure 10, the temperature data are shown with the different Rayleigh cross sections included. It was found that without any optimization to the plasma, the gas in the plasma center can reach temperatures of up to 5,000 K. It has been shown in Ar plasmas that the Thomson scattering and scattering from excited species becomes significant if the temperature reaches the order of 10,000 K 18,19,20 , making the temperature measurement unreliable. Given the values of the differential cross sections for Rayleigh and Thomson scattering of 0.148·10 -30 m 2 and 7.94·10 -30 m 2 , respectively, an ionization degree of 1.9·10 -4 would be necessary for a…”
Section: Representative Resultsmentioning
confidence: 99%
“…The theory of Thomson scattering is explicated by many literatures [7][8][9][10][11]13]. Figure 2 shows the comparison between electron temperature for the pure helium arc with the water-cooled copper anode (left side) and that for the helium arc during welding (right side) under the same condition of 150 A in arc current and 5 mm in arc length.…”
Section: Temperature Distributions 21 Experimental Set Upmentioning
confidence: 99%
“…Recently, some of non-LTE states in GTA plasma were showed in case of the pure argon. Snyder et al directly measured temperatures of electron and heavy particle in DC plasma jet [7] and free-burning arc [8] at atmospheric pressure by the method of laser scattering measurement which needs no assumption of LTE. They showed that electron temperature was different from heavy particle temperature.…”
Section: Introductionmentioning
confidence: 99%