2016
DOI: 10.1134/s1061934816070029
|View full text |Cite
|
Sign up to set email alerts
|

Determination of gasoline and diesel residues on wool, silk, polyester and cotton materials by SPME–GC–MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0
1

Year Published

2017
2017
2021
2021

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 28 publications
0
5
0
1
Order By: Relevance
“…Aqel et al. utilized HS‐SPME in a study for assessing the persistence of medium to heavy ignitable liquid residue on common materials found in a fire compartment, namely wool, silk, cotton, and polyester. In this study, they were able to show the sensitivity PDMS‐SPME fiber allowed for the detection as low as 200 μL of each accelerant .…”
Section: Modified Sample Preparation Techniques For Fire Debris Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…Aqel et al. utilized HS‐SPME in a study for assessing the persistence of medium to heavy ignitable liquid residue on common materials found in a fire compartment, namely wool, silk, cotton, and polyester. In this study, they were able to show the sensitivity PDMS‐SPME fiber allowed for the detection as low as 200 μL of each accelerant .…”
Section: Modified Sample Preparation Techniques For Fire Debris Analysismentioning
confidence: 99%
“… utilized HS‐SPME in a study for assessing the persistence of medium to heavy ignitable liquid residue on common materials found in a fire compartment, namely wool, silk, cotton, and polyester. In this study, they were able to show the sensitivity PDMS‐SPME fiber allowed for the detection as low as 200 μL of each accelerant . Several studies were carried out to assess the transfer and persistence of petrol on similar materials (carpets, clothing, and shoes) using either DFLEX or ACS .…”
Section: Modified Sample Preparation Techniques For Fire Debris Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…Rozwiązaniem tego problemu wydaje się być zastosowanie bardziej wyrafinowanych metod badawczych dających nowe informacje o analizowanym przedmiocie. Wykorzystanie metod chromatograficznych, a w szczególności metody GC-MS [1,4,26,33], daje możli-wość wprowadzania nowych wskaźników, które będą różnico-wać "piki związków" nieoznaczanych za pomocą GC-FID itp. Pozyskane dane mogą dostarczyć informacji na temat wzajemnego oddziaływania pomiędzy składnikami benzyny w mieszankach, ujawniając charakter efektu mieszania.…”
Section: Możliwości Interpretacyjne Systemów Wykorzystujących Sztucznunclassified
“…In most cases, the PDP is not found in isolation but adheres to different surfaces (wood, rocks, cloth, flooring etc.). The absorption characteristics of the substrates may affect the evaporation rate of the PDP and consequently the analysis and the identification [ 8 ].…”
Section: Introductionmentioning
confidence: 99%