2000
DOI: 10.1007/bf02490691
|View full text |Cite
|
Sign up to set email alerts
|

Determination of grepafloxacin in plasma samples by HPLC: Application to clinical pharmacokinetic studies

Abstract: SummaryA sensitive HPLC assay for the determination of grepafloxacin (GRE) in biological samples is described. Sample preparations were carried out by adding phosphate buffer (pH 7.4, 0.1M), followed by extraction with trichloromethane. GRE and the internal standard, enrofloxacin (ENR), were separated on a reversed-phase column using an aqueous phosphate solution-acetonitrile (78 : 22) mobile phase. The concentrations of ENR and GRE eluting of the column with retention times of 2.55, and 4.90 min, respectively… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2001
2001
2008
2008

Publication Types

Select...
8

Relationship

6
2

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 13 publications
0
11
0
Order By: Relevance
“…Grepafl oxacin was assayed in plasma and ocular tissues according to a previously described HPLC method [7] .…”
Section: Hplc Grepafl Oxacin Assaymentioning
confidence: 99%
See 1 more Smart Citation
“…Grepafl oxacin was assayed in plasma and ocular tissues according to a previously described HPLC method [7] .…”
Section: Hplc Grepafl Oxacin Assaymentioning
confidence: 99%
“…Grepafl oxacin, although not currently marketed, has exhibited good activity against many of the potential pathogens that may cause ocular infections [6] and has shown a good penetration into rabbit eye structures in both albino and pigmented rabbits [7] . Grepafl oxacin has also been shown to be a safe alternative for intravitreal injection in intraocular infections [8] .…”
Section: Introductionmentioning
confidence: 99%
“…Analytical Assay GRE was assayed in intravitreal fluid according to the previous HPLC method [10]. A Waters 501 HPLC pump and a Waters M717 autosampler were employed.…”
Section: Study Of Intravitreal Levelsmentioning
confidence: 99%
“…The eluate was continuously monitored by a Waters 420-AC fluorescence detector (Ïex 338 nm and Ïem 425 nm). The calculations were all carried out by an Integration pack program (Kontrol Instrument, Spain) [10].…”
Section: Study Of Intravitreal Levelsmentioning
confidence: 99%
“…Grepafl oxacin concentrations in the ocular tissues were determined by HPLC with fl uorescence detection according to a previously described analytical method [17] .…”
Section: Hplc Assay Of Grepafl Oxacinmentioning