2015
DOI: 10.1016/j.sab.2015.06.017
|View full text |Cite
|
Sign up to set email alerts
|

Determination of heavy metals in leather and fur by microwave plasma-atomic emission spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
22
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(23 citation statements)
references
References 17 publications
1
22
0
Order By: Relevance
“…Moreover, it can be noticed that, except for Cd, the estimated LOD and LOQ for MIP OES are lower (or very close to for Cu) than for ICP OES. Such observations, for various elements, have been reported by several authors: Li et al [5] for Mn, Zhao et al [6] for Ni and Pb, or Donati et al [2] for Cr, Ni, and Pb. Donati et al [2] proposed several hypotheses to support such observations.…”
Section: Limits Of Detection and Limits Of Quantificationsupporting
confidence: 66%
See 1 more Smart Citation
“…Moreover, it can be noticed that, except for Cd, the estimated LOD and LOQ for MIP OES are lower (or very close to for Cu) than for ICP OES. Such observations, for various elements, have been reported by several authors: Li et al [5] for Mn, Zhao et al [6] for Ni and Pb, or Donati et al [2] for Cr, Ni, and Pb. Donati et al [2] proposed several hypotheses to support such observations.…”
Section: Limits Of Detection and Limits Of Quantificationsupporting
confidence: 66%
“…Studies comparing the results obtained by MIP OES and other techniques are, however, rather few, particularly when focusing on the elements Cd, Cr, Cu, Cd, Ni, Pb, and Zn. A few studies offer comparisons with the results obtained by ICP OES [5,6], but again, the number of analytes and/or matrices and is often restricted.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, quick and accurate identification of Cd(II) concentrations is urgent to prevent soil pollution and ensure food safety. Up to now, the regular methods have been employed for Cd(II) determination, such as X fluorescence spectrometry (XRF) [ 12 ], Atomic Absorption Spectroscopy (AAS) [ 13 ], Atomic Emission Spectrometry(AES) [ 14 ], Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) [ 15 ], Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) [ 16 ], Atomic Fluorescence Spectrometry (AFS) [ 17 ], biological technique [ 18 ] and electrochemical method [ 19 ]. However, the spectrographic methods are not suitable for in-situ analysis because of complex operation, large volume, and expensive instruments.…”
Section: Introductionmentioning
confidence: 99%
“…The new method has already been applied for several purposes yet many fields of application is still open to the MP-AES technique [19]- [22].…”
Section: Introductionmentioning
confidence: 99%
“…The biological components are the most sensitive to the environmental change and tend to degrade upon human activity [19][20][21][22][23][24]. The chemical composition of soil is also an important parameter and can indicate pollution both from natural and anthropogenic origin.…”
Section: Introductionmentioning
confidence: 99%