2008
DOI: 10.1007/s00216-008-2135-4
|View full text |Cite
|
Sign up to set email alerts
|

Determination of illicit and medicinal drugs and their metabolites in oral fluid and preserved oral fluid by liquid chromatography–tandem mass spectrometry

Abstract: An LC-MS/MS method using 0.5 ml of oral fluid was developed for the determination of morphine, codeine, 6-monoacetylmorphine, methadone, amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxy-N-ethylamphetamine, benzoylecgonine, cocaine, delta-9-tetrahydrocannabinol, zolpidem, zopiclone, alprazolam, clonazepam, oxazepam, nordiazepam, lorazepam, flunitrazepam, diazepam, diphenhydramine and amitriptyline. The method was fully validated in terms of linea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
63
0
4

Year Published

2009
2009
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 94 publications
(68 citation statements)
references
References 12 publications
1
63
0
4
Order By: Relevance
“…The collected volumes of oral fluid were determined for each sample by weight. Drug concentrations in undiluted oral fluid were calculated by considering oral fluid density as 1 g/ml (Concheiro, de Castro, Quintela, Cruz, & Ló pez-Rivadulla, 2008). The analyses were carried out at both times by the University of Santiago de Compostela.…”
Section: Substances Analyzed and Toxicological Aspectsmentioning
confidence: 99%
“…The collected volumes of oral fluid were determined for each sample by weight. Drug concentrations in undiluted oral fluid were calculated by considering oral fluid density as 1 g/ml (Concheiro, de Castro, Quintela, Cruz, & Ló pez-Rivadulla, 2008). The analyses were carried out at both times by the University of Santiago de Compostela.…”
Section: Substances Analyzed and Toxicological Aspectsmentioning
confidence: 99%
“…The automated SPE method is simple and has few steps, allowing for effective processing of large numbers of samples. An LC-MS/MS method with automated SPE that uses a Gilson robot for the extraction was recently reported (8 ). The authors used different SPE columns and solvent for elution than we did, and had a low recovery for benzoylecgonine (7.5%), whereas our method showed 66% recovery for benzoylecgonine.…”
Section: Discussionmentioning
confidence: 76%
“…To fulfill this demand, it is important to have good recoveries for all of the compounds measured, which may be difficult to attain (7,8 ). In the initial development phase of our method, we focused on attaining adequate recoveries for THC, buprenorphine, and morphine, and succeeded in achieving recoveries exceeding 50% for all of the compounds but THC (32%-36%, which was found to be acceptable).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Certains auteurs l'utilisent également pour les cheveux [28,29,32] ou le fluide oral [41,[62][63][64].…”
Section: Extraction Sur Phase Solideunclassified