OPTIMATION OF DECY-13 CYCLOTRON MAGNET MAPPING SYSTEM.A cyclotron magnet serves to deflect the particle beam so that the beam trajectory is circular and also serves to focus the beam. The magnetic flux density of a cyclotron magnet must satisfy the isochronous curve. The magnetic field distribution need to be measured in order to know that the magnetic flux density has fulfilled the isochronous curve, therefore a mapping system is needed to obtain the magnetic field distribution data. The design and construction of mechanical system of magnetic field mapping has been carried out in 2013 using fly mode algorithm, but the test results is not accurate yet. Therefore it is necessary to optimize of the magnetic field mapping system. The aim of this optimation is to improve the accuracy of step position and the precission of magnetic field measurement of the mapping system of DECY-13 cyclotron magnet. The research was done by changing the mapping methods that previously based on the fly mode with the step mode. In the step mode, the magnetic field data would be taken when the probe has been completely stopped at the specified position. The magnet mapping system has been optimized with 89.58% of the average step position accuracy. The mapping system has to be started at minimum of 2 hours after the Magnet Power Supply (MPS) is turned on, in order to get 3.53 gauss of the precision of magnetic field measurement. Although the magnetic field measurement of 1 st sensor and 2 nd sensor have measurement maximum different of 6.3 gauss but the two sensors have the same pattern of magnetic field average. The mapping result from one of 2 sensors can be used to calculate magnetic field parameter if the magnetic field is symmetric.
ABSTRAK
OPTIMASI SISTEM PEMETAAN MAGNET SIKLOTRON DECY-13.Magnet siklotron berfungsi untuk membelokkan berkas partikel sehingga lintasan berkasnya melingkar dan juga berfungsi untuk memfokuskan berkas. Rapat fluks magnet dari magnet siklotron harus memenuhi kurva isochronous. Distribusi medan magnet perlu diukur untuk mengetahui bahwa rapat fluks magnet telah memenuhi kurva isochronous, oleh karena itu sistem pemetaan diperlukan untuk memperoleh data distribusi medan magnet. Desain dan konstruksi sistem mekanik pemetaan medan magnet telah dilakukan pada tahun 2013 dengan menggunakan algoritma fly mode, tetapi dari hasil pengujian, sistem pemetaan belum akurat. Oleh karena itu perlu untuk mengoptimalkan sistem pemetaan medan magnet. Tujuan dari optimasi ini adalah untuk meningkatkan akurasi posisi langkah dan presisi pengukuran medan magnet dari sistem pemetaan magnet siklotron Decy-13. Penelitian ini dilakukan dengan mengubah metode pemetaan yang sebelumnya menggunakan fly mode menjadi step mode. Pada pemetaan step mode, data medan magnet akan diambil ketika probe telah benarbenar berhenti pada posisi yang ditentukan. Sistem pemetaan magnet telah dioptimasi dengan akurasi ratarata posisi langkah 89,58%. Sistem pemetaan harus dimulai minimal 2 jam setelah Magnet Power Supply (MPS) diaktifkan untuk mendapa...