2017
DOI: 10.1002/jssc.201700543
|View full text |Cite
|
Sign up to set email alerts
|

Determination of methyl methanesulfonate and ethyl methanesulfonate in methanesulfonic acid by derivatization followed by high‐performance liquid chromatography with ultraviolet detection

Abstract: Methanesulfonic acid is routinely used in pharmaceuticals but can contain potentially genotoxic impurities such as methyl methanesulfonate and ethyl methanesulfonate. The aim of this study was to develop a simple high-performance liquid chromatography with ultraviolet detection method for determining methyl methanesulfonate and ethyl methanesulfonate in methanesulfonic acid. Samples (250 mg) in water/acetonitrile (200 μL) were first combined with 10.0 mol/L sodium hydroxide solution (270 μL). Then they were mi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…Zhou et al in 2017 applied two methods of analysis for MMS and EMS in MSA; data on three batches (grade and/or purity unspecified) are shown in Table .…”
Section: Technical Updatementioning
confidence: 99%
See 1 more Smart Citation
“…Zhou et al in 2017 applied two methods of analysis for MMS and EMS in MSA; data on three batches (grade and/or purity unspecified) are shown in Table .…”
Section: Technical Updatementioning
confidence: 99%
“…Pharmagrade MSA is readily available however usually marketed with an impurity specification of MMS, EMS, IMS, and MsCl all ≤5 ppm. 27 Zhou et al in 2017 28 applied two methods of analysis for MMS and EMS in MSA; data on three batches (grade and/or purity unspecified) are shown in Table 2.…”
Section: Box 1 Original Pheur Production Statement For Mesilate Salt ...mentioning
confidence: 99%
“…Therefore, adding UV chromophore by pre-column derivatization is required to improve the feasibility and sensitivity of the HPLC–UV assay. Zhou et al [ 22 ] successfully determined the content of MMS and EMS in MSA by the HPLC–UV method with the use of sodium N , N -diethyldithiocarbamate (DDTC) as a derivatization reagent. However, this method could not be used for the determination of PGIs in API because of the interference of the drug matrix.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, alkyl sulfonates and dialkylsulfonates in drug substances were detected by electrospray ionization mass spectrometry detection and hydrophilic interaction chromatography separation technique (An et al, 2008). The HPLC-UV method was employed to detect the methyl and ethyl mesylates and tosylates by derivatization (Li et al, 2019;Nageswari et al, 2011;Wang et al, 2022), and at an LOQ of 0.60 ppm was effective in the detection of EMS and MMS (Zhou et al, 2017).…”
Section: Introductionmentioning
confidence: 99%