2016
DOI: 10.1120/jacmp.v17i4.6190
|View full text |Cite
|
Sign up to set email alerts
|

Determination of MLC model parameters for Monaco using commercial diode arrays

Abstract: Multileaf collimators (MLCs) need to be characterized accurately in treatment planning systems to facilitate accurate intensity‐modulated radiation therapy (IMRT) and volumetric‐modulated arc therapy (VMAT). The aim of this study was to examine the use of MapCHECK 2 and ArcCHECK diode arrays for optimizing MLC parameters in Monaco X‐ray voxel Monte Carlo (XVMC) dose calculation algorithm. A series of radiation test beams designed to evaluate MLC model parameters were delivered to MapCHECK 2, ArcCHECK, and EBT3… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
29
0
4

Year Published

2017
2017
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(33 citation statements)
references
References 24 publications
0
29
0
4
Order By: Relevance
“…Besides less complexity, another advantage of using VSMs is fas- The relationship between appropriate modeling of the MLC leaf parameters and accurate dose calculations in treatment planning systems has been investigated by several research groups. [25][26][27] Bedford et al 25 verified the performance of the Agility MLC model implemented in the beam model of the Pinnacle 3 (Philips Radiation Oncology System, Fitchburg, WI, USA) for calculations and delivery of VMAT plans. Kinsella et al 26 and Synder et al 27 used specifically designed measurements to fine tune model parameters (e.g., leaf transmission, groove width, interleaf leakage) of the Agility MLC model implemented in the Monaco treatment planning system.…”
Section: Introductionmentioning
confidence: 99%
“…Besides less complexity, another advantage of using VSMs is fas- The relationship between appropriate modeling of the MLC leaf parameters and accurate dose calculations in treatment planning systems has been investigated by several research groups. [25][26][27] Bedford et al 25 verified the performance of the Agility MLC model implemented in the beam model of the Pinnacle 3 (Philips Radiation Oncology System, Fitchburg, WI, USA) for calculations and delivery of VMAT plans. Kinsella et al 26 and Synder et al 27 used specifically designed measurements to fine tune model parameters (e.g., leaf transmission, groove width, interleaf leakage) of the Agility MLC model implemented in the Monaco treatment planning system.…”
Section: Introductionmentioning
confidence: 99%
“…To adjust the MLC parameters in the human medicine, diodes, such as MapCHECK 2, Gafchromic EBT3 film, and ionization chambers were used in the study ( Grofsmid et al ., 2010 ; Kinsella et al ., 2016 ; Roche et al ., 2018 ). Dosimetric validation of a commercial AAPM TG-106 proposes the use of films, portal images, or diodes as measurement devices to determine MLC parameters ( Das et al ., 2008 ).…”
Section: Discussionmentioning
confidence: 99%
“…En primer lugar, fueron verificados 8 campos predefinidos en el acelerador: 3ABUT, 7SEC, FOURL, DMLC, HIMRT y HDMLC ¶ ; 17 10 × 10 cm 2 ; 20 × 20 cm 2 . Y en segundo lugar, fueron medidos 43 tratamientos completos de pacientes: 6 SBRT (Stereotactic Body Radiotherapy), 9 próstatas, 10 ORL (lesiones tumorales derivadas de otorrinolaringología), 9 pulmones, 5 cérvix, 1 columna, 1 hígado, 1 inguinal y 1 radiocirugía.…”
Section: Verificación Tratamientos Vmatunclassified