1981
DOI: 10.1016/s0021-9673(00)82701-6
|View full text |Cite
|
Sign up to set email alerts
|

Determination of molecular-weight distribution of polymers by microcolumn exclusion chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

1982
1982
1998
1998

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…10 Ishii and Takeuchi 11,12 illustrated that the high permeability of microscale columns made highly efficient separations (100 000 plates) possible by SEC. Others have illustrated useful applications of microscale SEC [13][14][15] and discussed optimum instrumentation for the technique. 16 Due to the small volumes involved in microscale separations, the extracolumn contribution to band broadening must be carefully controlled.…”
Section: Microscale Chromatography Has Found Numerous Applications In...mentioning
confidence: 99%
See 1 more Smart Citation
“…10 Ishii and Takeuchi 11,12 illustrated that the high permeability of microscale columns made highly efficient separations (100 000 plates) possible by SEC. Others have illustrated useful applications of microscale SEC [13][14][15] and discussed optimum instrumentation for the technique. 16 Due to the small volumes involved in microscale separations, the extracolumn contribution to band broadening must be carefully controlled.…”
Section: Microscale Chromatography Has Found Numerous Applications In...mentioning
confidence: 99%
“…Ishii and Takeuchi , illustrated that the high permeability of microscale columns made highly efficient separations (100 000 plates) possible by SEC. Others have illustrated useful applications of microscale SEC and discussed optimum instrumentation for the technique …”
mentioning
confidence: 99%
“…In this case the pressure in the pump chamber increases from P, = QK (6) to P' = QK' (7) for the time…”
Section: Optimization Of the Eluent Delivery System For Msecmentioning
confidence: 99%
“…They compare the column's performance with that of a commercial high-performance SEC column and evaluate the effects of column temperature and of varying the column inner diameter on the resolution. Kever et al (16B,17B,18B) develop high-resolution microcolumns (0.6 X 300 mm) with a mixed silica bed. Heitz (9B) obtains high resolution in the SEC analysis of oligomers using a coiled column of poly(tetrafluoroethylene) tubing and a "soft" poly(vinyl acetate) gel packing.…”
Section: Columns and Column Packing Materialsmentioning
confidence: 99%