2014
DOI: 10.4491/ksee.2014.36.11.764
|View full text |Cite
|
Sign up to set email alerts
|

Determination of N-nitrosamines in Water by Gas Chromatography Coupled with Electron Impact Ionization Tandem Mass Spectrometry

Abstract: This study assessed analysis of N-nitrosamines by separation, identification, and quantification using a gas chromatography (GC) mass spectrometer (MS) with electron impact (EI) mode. Samples were pretreated by a automated solid phase extraction (SPE) and a nitrogen concentration technique to detect low concentration ranges. The analysis results by EI-GC/MS (SIM) and EI-GC/ MS/MS (MRM) on standard samples with no pretreatment exhibited similar results. On the other hand, the analysis of pretreated samples at l… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 17 publications
0
2
0
Order By: Relevance
“…The analytical conditions for GC and LC were optimized by referring to previous studies on the simultaneous analysis of nitrosamines using GC-MS/MS and LC-MS/MS, and the nitrosamine analysis guidelines of domestic and overseas countries. In previous studies using GC [13][14][15][16][17], the WAX column in which the stationary phase is ethylene glycol is used most frequently in the analysis of nitrosamines. We selected the DB-WAX UI (30 m × 0.25 mm, 0.25 µm) column accordingly.…”
Section: Optimization Of Gc and Lc Conditions For The Simultaneous Analysis Of Nine Nitrosamines In Artificial Salivamentioning
confidence: 99%
See 1 more Smart Citation
“…The analytical conditions for GC and LC were optimized by referring to previous studies on the simultaneous analysis of nitrosamines using GC-MS/MS and LC-MS/MS, and the nitrosamine analysis guidelines of domestic and overseas countries. In previous studies using GC [13][14][15][16][17], the WAX column in which the stationary phase is ethylene glycol is used most frequently in the analysis of nitrosamines. We selected the DB-WAX UI (30 m × 0.25 mm, 0.25 µm) column accordingly.…”
Section: Optimization Of Gc and Lc Conditions For The Simultaneous Analysis Of Nine Nitrosamines In Artificial Salivamentioning
confidence: 99%
“…In the past, the GC method mainly referred to the gas chromatography-thermal energy analysis (GC-TEA), which is a traditional method with a high selectivity for Nnitroso compounds using thermal decomposition [12]. However, since MS with a higher sensitivity than GC-TEA has been developed, GC-MS(MS) (single or tandem MS) has been applied to analyze nitrosamines in several studies, as well as in Method 521 of the U.S. EPA [13][14][15][16][17]. The LC method has been reported to enable the simultaneous measurement of nitrosamines eluted into artificial saliva and has been verified as an alternative to the traditional GC-TEA method of the EU [2].…”
Section: Introductionmentioning
confidence: 99%