Determination of nevirapine, an HIV-1 non-nucleoside reverse transcriptase inhibitor, in human plasma by reversed-phase high-performance liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
38
0

Year Published

2002
2002
2018
2018

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(40 citation statements)
references
References 6 publications
2
38
0
Order By: Relevance
“…176,2003) showed that the combination of NVP and EFZ did not provide additive benefit and, moreover, increased the adverse side effects. The present assay was also highly sensitive, with a detection limit of 100 pg ml Ϫ1 , which compares favorably with those previously reported for UV and tandem mass spectrometry methods: close to 50 (6,10,22) and 10 (14) ng ml Ϫ1 , respectively. The accuracy and precision of the EIA were also good, so the assay is useful for pharmacokinetic studies.…”
Section: Discussionsupporting
confidence: 89%
See 1 more Smart Citation
“…176,2003) showed that the combination of NVP and EFZ did not provide additive benefit and, moreover, increased the adverse side effects. The present assay was also highly sensitive, with a detection limit of 100 pg ml Ϫ1 , which compares favorably with those previously reported for UV and tandem mass spectrometry methods: close to 50 (6,10,22) and 10 (14) ng ml Ϫ1 , respectively. The accuracy and precision of the EIA were also good, so the assay is useful for pharmacokinetic studies.…”
Section: Discussionsupporting
confidence: 89%
“…Several high-performance liquid chromatographic (HPLC) assays combined with UV detection (6,10,22) or tandem mass spectrometry (14,24) for the quantitative determination of NVP in plasma have been described. However, these methods are characterized by a relatively high limit of quantification (10 ng ml Ϫ1 ) and by fastidious workup, thus excluding their use in the ex vivo monitoring of intracellular levels of the drug.…”
mentioning
confidence: 99%
“…Data were collected on standardized forms from clinical case notes and computer-based medical records. We verified the data for all pregnant patients manually using the clinical case notes.Plasma concentrations of NVP were determined using a validated high-performance liquid chromatography assay with ultraviolet detection, with a modification described previously [18]. Although a clear cut-off value (below which a statistically significant increased risk of virological failure occurs) is lacking, an increased risk of virological failure is observed when random NVP plasma concentrations are below 3.0 mg/L [16,19,20].…”
mentioning
confidence: 99%
“…The concentration of nevirapine in the plasma samples was analyzed by modified reported methods (Hollanders et al, 2000;Kabra et al, 2009;Minzi & Ngaimisi, 2010). The HPLC apparatus consisted of Jasco PU-980 Intelligent HPLC pump (Jasco, Japan) equipped with a Jasco UV-975 Intelligent UV/VIS detector (Jasco, Japan), an autosampler Jasco AS-950-10 Intelligent sample (Jasco, Japan), a Jasco Borwin chromatography software (version 1.50) integrator software and a LCGC Qualisil BDS C18 (4.6 mm  250 mm and 5 mm particle size) column.…”
Section: Hplc Analysismentioning
confidence: 99%