1987
DOI: 10.1016/s0021-9673(01)94602-3
|View full text |Cite
|
Sign up to set email alerts
|

Determination of non-protein α-alkyl-α-amino acids by reversed-phase high-performance liquid chromatography in comparison with ion-exchange and capillary gas chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1987
1987
2013
2013

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(3 citation statements)
references
References 49 publications
0
3
0
Order By: Relevance
“…However, Aib and C°-MeLeu react considerably more slowly than the -amino acids and would need a 10-and 15-min reaction time, respectively, to reach their maximum fluorescence. 41 As a result, Aib gave a very low but quantifiable signal, while C"-MeLeu could not be detected in our system. A precolumn derivatization would appear to be necessary, but we envisage that other inefficiencies would result due to the relative instability of some OPA-adducts like OPAglycine.41 So, amino acid analysis of C°-methyl amino acid-containing peptides was coupled to mass spectrometry to confirm their structure (see Table I).…”
Section: Resultsmentioning
confidence: 68%
See 1 more Smart Citation
“…However, Aib and C°-MeLeu react considerably more slowly than the -amino acids and would need a 10-and 15-min reaction time, respectively, to reach their maximum fluorescence. 41 As a result, Aib gave a very low but quantifiable signal, while C"-MeLeu could not be detected in our system. A precolumn derivatization would appear to be necessary, but we envisage that other inefficiencies would result due to the relative instability of some OPA-adducts like OPAglycine.41 So, amino acid analysis of C°-methyl amino acid-containing peptides was coupled to mass spectrometry to confirm their structure (see Table I).…”
Section: Resultsmentioning
confidence: 68%
“…This results in very low color yields with ninhydrin (under standard conditions, ninhydrin color yield of Aib and C"-MeLeu relative to Leu are 7.4 and 9.4%, respectively, as determined by Brückner et al). 41 This property results in less accurate monitoring of the subsequent coupling step by the Kaiser test. 42 We systematically repeated this particular step three times with large excesses of Boc-amino acid and DIC and then deblocked an aliquot of the resin with TFA.…”
Section: Resultsmentioning
confidence: 99%
“…Highly sensitive determination of <-(7-glutamyl)lysine cross-links has been performed by liberation of the crosslink by exhaustive proteolytic digestion and derivatization with o-phthalaldehyde (OPA) followed by highperformance liquid chromatography (HPLC) separation (Griffin et al, 1982;Beninati et al, 1988; Nonaka et al, 1989; Tanaka et al, 1990;Kimura et al, 1991). It has been, however, demonstrated that the fluorescence intensity of OPA-2-mercaptoethanol derivatives depends on temperature and reaction time (Brückner et al, 1987). Moreover, the relative fluorescence of 0PA-e-(7-glutamyl)lysine decreases to 83 % of its initial value after only 45 min in storage (Griffin et al, 1982).…”
Section: Introductionmentioning
confidence: 99%