2014
DOI: 10.1148/radiol.14131251
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Normal Hepatic Elasticity by Using Real-time Shear-wave Elastography

Abstract: Hepatic elasticity values measured with SWE in histologically proven normal livers ranged from 2.6 to 6.2 kPa, with high measurement reliability. The effect of the potential confounding factors on liver elasticity was negligible.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

9
55
0
2

Year Published

2017
2017
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 78 publications
(66 citation statements)
references
References 32 publications
9
55
0
2
Order By: Relevance
“…In our experiment, SWE showed an excellent methodology stability and reliability. This conclusion was consistent with the findings in previous studies (31,32).…”
Section: Discussionsupporting
confidence: 94%
“…In our experiment, SWE showed an excellent methodology stability and reliability. This conclusion was consistent with the findings in previous studies (31,32).…”
Section: Discussionsupporting
confidence: 94%
“…Con respecto a los 33 sujetos analizados, se observó una diferencia entre el grupo de hombres y mujeres en los valores de rigidez hepática; estos mismos resultados se observaron en otros estudios. En el estudio de Suh y colaboradores (19), con 196 donantes potenciales para trasplante de hígado con donante vivo, el rango de referencia para la elasticidad hepática normal confirmada por biopsia fue 2,6-6,2 kPa, con una elasticidad media de 4,4 kPa. El valor medio de elasticidad hepática normal en nuestro estudio fue 4,28 kPa, que está en concordancia con los datos de Suh (en cuyo estudio la mayoría eran sujetos delgados similares a los nuestros) y con valores obtenidos en voluntarios sanos sin corroboración histológica (4,6-4,9 kPa) (20).…”
Section: Discussionunclassified
“…In three studies, the intraobserver reproducibility of SSI during the same session was excellent (ICC ranged from 0.92 to 0.95) [23,73,118]. The interobserver agreement on different days was affected by operator experience and ranged from 0.63 to 0.84 [23,118].…”
Section: Reproducibility In Healthy Subjectsmentioning
confidence: 92%
“…2D-SWE measurements of Young's modulus using supersonic shear imaging (SSI) in healthy subjects cover the range 4.5 -5.5 kPa (95 th percentile 6.2 kPa) [73,74]. Healthy men may have higher LSMs than healthy women, while BMI and age do not seem to influence LSM in subjects without liver disease [74].…”
Section: Recommendationmentioning
confidence: 99%