1996
DOI: 10.1016/0021-9673(96)00351-2
|View full text |Cite
|
Sign up to set email alerts
|

Determination of paclitaxel in biological fluids by micellar electrokinetic chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
28
0

Year Published

1997
1997
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 68 publications
(28 citation statements)
references
References 9 publications
0
28
0
Order By: Relevance
“…Taxoids have been analyzed by thin-layer chromatography (TLC) (Fujino et al, 2001), high-performance liquid chromatographyphotodiode array detection (HPLC-PAD) (Neméth-Klss et al, 1996), high-performance liquid chromatography-UV detection (HPLC-UV; Theodoridis et al, 1998), micellar electrokinetic capillary chromatography (MECC; Hempel et al, 1996) and high-speed counter-current chromatography (HSCCC; Cao et al, 1998). Short-term methods to determine taxoids have been described using HPLC-MS (Madhusudanan et al, 2002a,b;Kuppens et al, 2005;Mroczek et al, 2000;Mortier et al, 2004).…”
Section: Simultaneous Determination Of Main Taxoids Inmentioning
confidence: 99%
“…Taxoids have been analyzed by thin-layer chromatography (TLC) (Fujino et al, 2001), high-performance liquid chromatographyphotodiode array detection (HPLC-PAD) (Neméth-Klss et al, 1996), high-performance liquid chromatography-UV detection (HPLC-UV; Theodoridis et al, 1998), micellar electrokinetic capillary chromatography (MECC; Hempel et al, 1996) and high-speed counter-current chromatography (HSCCC; Cao et al, 1998). Short-term methods to determine taxoids have been described using HPLC-MS (Madhusudanan et al, 2002a,b;Kuppens et al, 2005;Mroczek et al, 2000;Mortier et al, 2004).…”
Section: Simultaneous Determination Of Main Taxoids Inmentioning
confidence: 99%
“…Particularly for the most widely used UV absorbance detection, the concentration detection limit is generally on the order of 10 -100-fold higher than that of HPLC due to the short optical pass-length. Improvement of the capillary geometry and optical design, such as use of a bent capillary (Z-cell) [3], a silver-coated capillary (multireflection flow cell) [4], a bubble-cell or extended light part capillary [5][6][7], end-column [8] and off-column [9] detections, is one approach to lower the detection limit of CE. Another effective approach is sample concentration [2].…”
Section: Introductionmentioning
confidence: 99%
“…The reported methods, however, had some drawbacks. TLC [28,29], MECC [30,31] and high-speed counter-current chromatography (HSCCC) [32,33] all can separate taxoids, but they cannot adapt to mass production. Chemical reac-tion method was used to separate taxoids with the transformed structures [34,35], but it needs strict reaction condition and is difficult to control.…”
Section: Introductionmentioning
confidence: 99%