2009
DOI: 10.1016/j.sab.2009.07.014
|View full text |Cite
|
Sign up to set email alerts
|

Determination of phosphorus in steel by the combined technique of laser induced breakdown spectrometry with laser induced fluorescence spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(14 citation statements)
references
References 18 publications
0
14
0
Order By: Relevance
“…Under this category, the underlying purpose is either to improve the information power of the approach, i.e., by providing both molecular as well as elemental information, as in the coupling of LIBS with Raman spectroscopy, 394,,–403 or again to improve the sensitivity (laser ablation–laser-induced fluorescence, LA-LIF). 404,,–420…”
Section: Review Outlinementioning
confidence: 99%
See 2 more Smart Citations
“…Under this category, the underlying purpose is either to improve the information power of the approach, i.e., by providing both molecular as well as elemental information, as in the coupling of LIBS with Raman spectroscopy, 394,,–403 or again to improve the sensitivity (laser ablation–laser-induced fluorescence, LA-LIF). 404,,–420…”
Section: Review Outlinementioning
confidence: 99%
“…The emphasis is on its quantitative aspects and improvement in sensitivity and detection limits. The fluorescence experiments reported below have been performed with pulsed frequency-doubled tunable dye lasers, 406,,–408,412,,–414 frequency-doubled and -tripled Ti-sapphire lasers, 411,416 and OPO tunable lasers. 418,419…”
Section: Hyphenated (Tandem) Approachesmentioning
confidence: 99%
See 1 more Smart Citation
“…We attempted to discern the spectral characteristics of the S atom and ion, but the characteristics were not found. Spectral characteristics of P and S in the ultraviolet band are much stronger than their visible band characteristics [43,44,45]. However, an ultraviolet spectrometer requires a vacuum environment; thus, it is difficult to use in-field.…”
Section: Resultsmentioning
confidence: 99%
“…However, a signal improvement can also be obtained by improving the conventional LIBS system, e.g. using a resonant excitation system [18] or double pulse (DP) LIBS [17,[19][20][21][22][23][24][25][26][27][28][29][30][31][32].…”
Section: Introductionmentioning
confidence: 99%