Determination of Phthalates into Vegetable Oils by Isotopic Dilution Gas Chromatography Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(12 citation statements)
references
References 16 publications
0
11
0
Order By: Relevance
“…The HP‐5MS UI (30 m × 0.25 mm × 0.25 μm) column was chosen for the separation of 16 PAEs . Figure shows the total ion chromatography of the 16 PAEs.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The HP‐5MS UI (30 m × 0.25 mm × 0.25 μm) column was chosen for the separation of 16 PAEs . Figure shows the total ion chromatography of the 16 PAEs.…”
Section: Resultsmentioning
confidence: 99%
“…SPME is suitable for the analysis of PAEs in water , but it appears not applicable to alcoholic samples because the PAEs are very soluble in ethanol and lead to poor extraction efficiency. As a consequence, accuracy of the analytical methods is compromised . Gel permeation chromatography is often used for the fatty food to remove fat before chromatographic analysis .…”
Section: Introductionmentioning
confidence: 99%
“…Stir well and wait for 1.5-2 h to ensure the gel completely solidifies. 4. Analyze the results of the cycle optimization: combine 1 µL of each PCR product with 5 µL of RNA loading buffer (62.5% formamide, 0.4 M formaldehyde, 1.25×3-(N-morpholino) propansulfonic acid buffer, 0.02% xylene cyanol FF, 0.02% bromophenol blue), and 4 µL of RNase-free water; heat the mixture at 95 °C for 10 min, and quickly cool it to 0 °C on ice; incubate for 5 min at room temperature; load into 5 separate wells of the 12% denatured PAGE; run electrophoresis by a vertical electrophoresis system in 1 × TBE buffer at 170 V for 45 min.…”
Section: Selexmentioning
confidence: 99%
“…For example, the most toxic POPs include polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), polybrominated biphenyl ethers (PBDEs), polychlorinated dibenzo-p-dioxin (PCDDs), polychlorinated dibenzofuran (PCDFs), and phthalic acid esters (PAEs) 1,2 , which all consist of many congeners. Small molecule detection has been mainly performed by chromatography/mass spectrometry-based techniques due to their diversity of applications 3,4,5,6 . For on-site detections, antibody-based methods have recently been developed 7,8,9 .…”
Section: Introductionmentioning
confidence: 99%
“…The most popular methods for PAEs detection are based on chromatography. [16][17][18][19][20][21] These chromatographic-based methods are sensitive, high-throughput and accurate. However, due to the relatively low concentration level of PAEs and the interference of coexistence, direct analysis of PAEs remains a great challenge.…”
Section: Introductionmentioning
confidence: 99%