1983
DOI: 10.1021/ac00258a015
|View full text |Cite
|
Sign up to set email alerts
|

Determination of picogram quantities of uranium in biological tissues by isotope dilution thermal ionization mass spectrometry with ion counting detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

1985
1985
2017
2017

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 47 publications
(14 citation statements)
references
References 41 publications
0
14
0
Order By: Relevance
“…Thermal ionization mass spectrometry (TIMS) [16] also provides accurate and precise measurements, but is not practical for large number of patient screenings since extensive sample preparations are required [2,[16][17][18]. Alpha and gamma particle spectrometries have also been used [19][20][21][22] but require long counting times, removal of uranium from the matrix and display detection limits 2-3 orders of magnitude worse than ICP-MS.…”
Section: Introductionmentioning
confidence: 99%
“…Thermal ionization mass spectrometry (TIMS) [16] also provides accurate and precise measurements, but is not practical for large number of patient screenings since extensive sample preparations are required [2,[16][17][18]. Alpha and gamma particle spectrometries have also been used [19][20][21][22] but require long counting times, removal of uranium from the matrix and display detection limits 2-3 orders of magnitude worse than ICP-MS.…”
Section: Introductionmentioning
confidence: 99%
“…The constant bias of the analytical procedure can be evaluated by analyzing two different masses of samples and checking if both samples deliver the same result. It is estimated with the Youden method [ 29 , 30 ] according to ( 4 ): where b cte denotes the constant bias (expressed in ng), a i and a j are the mean values of the two masses of the subsamples for comparison, and x i and x j are the mean masses of quantified chlorinated compounds (ng).…”
Section: Methodsmentioning
confidence: 99%
“…Extractable ammonium and nitrate nitrogen (NH 4 + and NO 3 − ) were measured simultaneously in 2 mol/L KCl solution (1∶5 w/v) [53] using a Lachat Flow Injection Analyzer (Lachat Instruments, Milwaukee, WI). The amount of extractable ammonium and nitrate nitrogen were taken as total inorganic N. SOC was measured by the potassium dichromate oxidation method with ground air-dried soils [54] while STN was measured by Kjeldahl method [55]. Because of the minor variation of SOC and STN in our study sites over a year (data not shown), we only measured the values in summer time (July) and did not take the difference between summer and winter into consideration.…”
Section: Methodsmentioning
confidence: 99%