2021
DOI: 10.1088/1361-6587/abf449
|View full text |Cite
|
Sign up to set email alerts
|

Determination of poloidal mode numbers of MHD modes and their radial location using a soft x-ray camera array in the Wendelstein 7-X stellarator

Abstract: A forward modeling technique is developed for determining the characteristic features of observed MHD modes from the line-of-sight data of the soft x-ray (SXR) tomography diagnostics in the Wendelstein 7-X (W7-X) stellarator. In particular, forward modeling is used to evaluate the poloidal mode numbers m, radial location, poloidal rotation direction and ballooning character of the MHD modes. The poloidal mode structures have been modeled by the radially localized Gaussian-shaped emission regions rotating along… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
9
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 14 publications
1
9
0
Order By: Relevance
“…In order to extract the information about the mode numbers and direction of the rotation from line-integrated SXR measurements, we first use a simplified eigenmode model for the mode pattern in the poloidal plane of the location of the MPX camera (cf figure 3(a)). This model is adopted from the model described in detail in [15]. It is possible to perform 'virtual measurement' along the lines-of-sight across the modeled xray radiation distribution.…”
Section: Forward Modeling By the Radially Localized Gaussian-shaped E...mentioning
confidence: 99%
See 4 more Smart Citations
“…In order to extract the information about the mode numbers and direction of the rotation from line-integrated SXR measurements, we first use a simplified eigenmode model for the mode pattern in the poloidal plane of the location of the MPX camera (cf figure 3(a)). This model is adopted from the model described in detail in [15]. It is possible to perform 'virtual measurement' along the lines-of-sight across the modeled xray radiation distribution.…”
Section: Forward Modeling By the Radially Localized Gaussian-shaped E...mentioning
confidence: 99%
“…Thus, the path of the mode perturbation in the 'far away' and the 'near plasma' parts with respect to the camera cannot be distinguished from the SXR data. The significant difference in the paths can be caused by the closer location of the SXR camera [15] or by the asymmetry of the magnetic flux surfaces [13]. So, the sign of m cannot be experimentally determined in TCV, and only the absolute value of m can be determined.…”
Section: Forward Modeling By the Radially Localized Gaussian-shaped E...mentioning
confidence: 99%
See 3 more Smart Citations