2010
DOI: 10.1016/j.aca.2010.07.010
|View full text |Cite
|
Sign up to set email alerts
|

Determination of polybrominated diphenyl ethers in fish tissues by matrix solid-phase dispersion and gas chromatography coupled to triple quadrupole mass spectrometry: Case study on European eel (Anguilla anguilla) from Mediterranean coastal lagoons

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
31
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 57 publications
(32 citation statements)
references
References 37 publications
1
31
0
Order By: Relevance
“…As described by Labadie et al 2010, POPs levels were blank corrected and the method detection limit (LoD) was derived from the blank value variability, For PCBs LoQs were comprised between 0.2 and 2 ng/g dw; for OCPs they were comprised between 0.1 and 0.4 ng/g dw; for PBDEs they were comprised between 0.1 and 0.2 ng/g dw.…”
Section: Organic Pollutants Analysesmentioning
confidence: 99%
“…As described by Labadie et al 2010, POPs levels were blank corrected and the method detection limit (LoD) was derived from the blank value variability, For PCBs LoQs were comprised between 0.2 and 2 ng/g dw; for OCPs they were comprised between 0.1 and 0.4 ng/g dw; for PBDEs they were comprised between 0.1 and 0.2 ng/g dw.…”
Section: Organic Pollutants Analysesmentioning
confidence: 99%
“…High recovery rates (greater than 70%) were achieved for all twenty-eight PBDEs, including perbrominated BDEs, though high solvent consumption was necessary (more than 100 mL per 3 g of freeze-dried sample) [57]. Miniaturization of MSPD using C 18 and Florisil as dispersants and acetonitrile:water as eluting solvent resulted in lower sample size (0.1 g) and low sorbent (0.4 g) and solvent (2.6 mL) request, with satisfactory recoveries (between 55% and 130%) for tetra-and penta-BDEs [71].…”
Section: Integrated Extraction and Cleanupmentioning
confidence: 99%
“…It seems that, regardless of matrix fat content, a single SPE step is enough to yield adequate recovery rates [46,56,57,66,67], although more exhaustive cleanup (up to three sequential SPE) can also be employed, even for low fat samples [58,68]. Additionally, different eluents can be sequentially added for fractionation, thus separating PBDEs from MeO-PBDEs and OH-PBDEs, in order to improve chromatographic resolution [69].…”
Section: Solid-phase Extractionmentioning
confidence: 99%
See 1 more Smart Citation
“…After analysis of PBDEs (see next section), F1 and F2 were combined, and the so-obtained extract was analyzed for PCBs (see next section). PBDE/PCB Analysis PBDE analysis was achieved using an Agilent 7890 A gas chromatograph coupled to an Agilent 7000 B triple quadripole mass spectrometer (GC-MS/MS; Agilent, Massy, France) as described by Labadie et al (2010a). PCB analysis was achieved with a 7890 A gas chromatograph coupled to a 5975 C mass spectrometer (Agilent Technologies).…”
Section: Extract Clean-up Proceduresmentioning
confidence: 99%